A novel forward-looking ultrasound catheter for treating vascular occlusions
Bibliographic record
Abstract
Thrombotic and chronic occlusions of large blood vessels are a major cause of mortality and morbidity, and so there is a need for improved treatments in many clinical circumstances. Endovascular ultrasound approaches have been shown to hold considerable potential to treat large vessel thrombotic occlusions. Here, we report the development of a novel forward-looking therapeutic ultrasound catheter approach. The design concept centers on the use of a radially polarized hollow cylindrical transducer situated at the distal tip. This approach enables a compact configuration where the central lumen can accommodate a guidewire during navigation as well as provide a route to release cavitation seeds and therapeutic agents adjacent to the site of occlusion. PZT-5H transducers with outer/inner diameters of 1.35/0.73 mm were evaluated using simulations and experiments for their capacity to project forward-looking ultrasound. A length of 2.5 mm operating in the 3rd harmonic of the length mode resonance (1.85 MHz) was selected. Catheters (1.55 mm outer diameter) were designed and fabricated with a liner, outer jacket, and braiding, where the transducers were incorporated with air-backing and a front-face matching layer. Forward-looking pressures of 2.5 MPa (peak negative) at 0.5 mm were achieved. Proof of principle vessel phantom experiments were performed demonstrating the ability to eject microbubbles in proximity to an occlusion and stimulate inertial cavitation. This approach holds potential for treating thrombotic and chronic total occlusions.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".