MétaCan
Menu
Back to cohort
Record W4398236700 · doi:10.1111/epi.18021

Detection of focal to bilateral tonic–clonic seizures using a connected shirt

2024· article· en· W4398236700 on OpenAlexafffund
Oumayma Gharbi, Yassine Lamrani, Jérôme St‐Jean, Amirhossein Jahani, Dènahin Hinnoutondji Toffa, Thi Phuoc Yen Tran, Manon Robert, Dang Khoa Nguyen, Elie Bou Assi

Bibliographic record

VenueEpilepsia · 2024
Typearticle
Languageen
FieldNeuroscience
TopicEEG and Brain-Computer Interfaces
Canadian institutionsUniversité de MontréalCentre Hospitalier de l’Université de Montréal
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchFonds de Recherche du Québec - SantéInstitut de Valorisation des DonnéesUniversité de Montréal
KeywordsReceiver operating characteristicEpilepsyMedicineFalse positive rateALARMConfidence intervalFalse alarmLatency (audio)Computer scienceArtificial intelligenceInternal medicineTelecommunications

Abstract

fetched live from OpenAlex

OBJECTIVE: This study was undertaken to develop and evaluate a machine learning-based algorithm for the detection of focal to bilateral tonic-clonic seizures (FBTCS) using a novel multimodal connected shirt. METHODS: We prospectively recruited patients with epilepsy admitted to our epilepsy monitoring unit and asked them to wear the connected shirt while under simultaneous video-electroencephalographic monitoring. Electrocardiographic (ECG) and accelerometric (ACC) signals recorded with the connected shirt were used for the development of the seizure detection algorithm. First, we used a sliding window to extract linear and nonlinear features from both ECG and ACC signals. Then, we trained an extreme gradient boosting algorithm (XGBoost) to detect FBTCS according to seizure onset and offset annotated by three board-certified epileptologists. Finally, we applied a postprocessing step to regularize the classification output. A patientwise nested cross-validation was implemented to evaluate the performances in terms of sensitivity, false alarm rate (FAR), time in false warning (TiW), detection latency, and receiver operating characteristic area under the curve (ROC-AUC). RESULTS: We recorded 66 FBTCS from 42 patients who wore the connected shirt for a total of 8067 continuous hours. The XGBoost algorithm reached a sensitivity of 84.8% (56/66 seizures), with a median FAR of .55/24 h and a median TiW of 10 s/alarm. ROC-AUC was .90 (95% confidence interval = .88-.91). Median detection latency from the time of progression to the bilateral tonic-clonic phase was 25.5 s. SIGNIFICANCE: The novel connected shirt allowed accurate detection of FBTCS with a low false alarm rate in a hospital setting. Prospective studies in a residential setting with a real-time and online seizure detection algorithm are required to validate the performance and usability of this device.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.305
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueEpilepsiaSame topicEEG and Brain-Computer InterfacesFrench-language works237,207