MétaCan
Menu
Back to cohort
Record W4399068534 · doi:10.1016/j.ajo.2024.05.008

Pars Plana Vitrectomy With Silicone Oil or Gas Tamponade for Uncomplicated Retinal Detachment: A Systematic Review and Meta-Analysis

2024· review· en· W4399068534 on OpenAlexaff
Ryan S. Huang, Andrew Mihalache, Tsz Hin Alexander Lau, Marko M. Popovic, Peter J. Kertes, Rajeev H. Muni

Bibliographic record

VenueAmerican Journal of Ophthalmology · 2024
Typereview
Languageen
FieldMedicine
TopicRetinal and Macular Surgery
Canadian institutionsSt. Michael's HospitalSunnybrook Health Science CentreHealth Sciences CentreMcGill UniversityUniversity of Toronto
Fundersnot available
KeywordsPars planaVitrectomyTamponadeRetinal detachmentSilicone oilMedicineOphthalmologyMeta-analysisRetinalMaterials scienceVisual acuityInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: To compare the efficacy and safety of pars plana vitrectomy (PPV) with silicone oil compared to gas tamponade for uncomplicated rhegmatogenous retinal detachment (RRD). DESIGN: Systematic review and meta-analysis. METHODS: A systematic literature search was conducted on Ovid MEDLINE, Embase, and the Cochrane Library from January 2000 to September 2023 for comparative studies evaluating the efficacy and safety of PPV with either silicone oil or gas tamponade in the setting of uncomplicated RRD. Our primary outcome was best-corrected visual acuity at the last study observation. Secondary outcomes included the rates of retinal reattachment, retinal thickness, and the incidence of adverse events. We performed a meta-analysis using a random-effects model. RESULTS: Nine observational studies reporting on 491 RRD eyes were included. The mean best-corrected visual acuity at the last study observation was significantly better in the gas tamponade group than in the silicone oil group (weighted mean difference [WMD] = 0.17 logMAR, 95% confidence interval [CI] = [0.06, 0.27], P = .002). Rates of primary retinal reattachment were similar between the silicone oil and gas tamponade groups (P = .89). The ganglion cell layer was significantly thinner in the silicone oil group compared to the gas tamponade group (WMD =-3.70 µm, 95% CI = [-5.87, -1.53, P = .0008), as was the inner plexiform layer (WMD = -2.45, 95% CI = [-4.50, -0.40], P = .02) and outer nuclear layer (WMD = -11.74 µm, 95% CI = [-18.39, -5.10], P = .0005). CONCLUSIONS: PPV with gas tamponade was associated with better functional outcomes compared to PPV with silicone oil, although both tamponades yielded comparable primary reattachment rates. The absence of randomized trials and the potential for selection bias underscore the importance of further investigation in diverse patient populations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Meta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.642
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0190.004
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.095
GPT teacher head0.393
Teacher spread0.298 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueAmerican Journal of OphthalmologySame topicRetinal and Macular SurgeryFrench-language works237,207