MétaCan
Menu
Back to cohort
Record W4399095448 · doi:10.1111/hdi.13162

Hemodynamic effects of low versus high dialysate bicarbonate concentration in hemodialysis patients

2024· article· en· W4399095448 on OpenAlexvenueno aff
Jonas Jensen, Ina Hunnerup Jørgensen, Niels Buus, Christian D. Peters

Bibliographic record

VenueHemodialysis International · 2024
Typearticle
Languageen
FieldMedicine
TopicRenal function and acid-base balance
Canadian institutionsnot available
FundersNyreforeningens ForskningsfondAarhus UniversitetshospitalAarhus Universitet
KeywordsMedicineHemodialysisHemodynamicsBicarbonateCardiologyInternal medicineIntensive care medicine

Abstract

fetched live from OpenAlex

INTRODUCTION: Hemodialysis treatment using standard dialysate bicarbonate concentrations cause transient metabolic alkalosis possibly associated with hemodynamic instability. The aim of this study was to perform a detailed comparison of high and low dialysate bicarbonate in terms of blood pressure, intradialytic hemodynamic parameters, orthostatic blood pressure, and electrolytes. METHODS: Fifteen hemodialysis patients were examined in a single-blind, randomized, controlled, crossover study. Participants underwent a 4-h hemodialysis session with dialysate bicarbonate concentration of 30 or 38 mmol/L with 1 week between interventions. Blood pressure was monitored throughout hemodialysis, while cardiac output, total peripheral resistance, stroke volume, and central blood volume were assessed with ultrasound dilution technique (Transonic). Orthostatic blood pressure was measured pre- and post-hemodialysis. FINDINGS: With similar ultrafiltration (UF) volume (2.6 L), systolic blood pressure (SBP) tended to decrease more during high dialysate bicarbonate compared to low dialysate bicarbonate; the mean (95% confidence interval) between treatment differences in SBP were: 8 (-4; 20) mmHg (end of hemodialysis) and 7 (0; 15) mmHg (post-hemodialysis). Stroke volume decreased whereas total peripheral resistance increased significantly more during high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment differences: Stroke volume: 12 (1; 23) mL; Total peripheral resistance: -2.9 (-5.3; -0.5) mmHg/(L/min). Cardiac output tended to decrease more with high dialysate bicarbonate compared to low dialysate bicarbonate with mean between treatment difference 0.7 (0.0; 1.4) L/min. High dialysate bicarbonate caused alkalosis, hypocalcemia, and lower plasma potassium, whereas patients remained normocalcemic with normal pH during low dialysate bicarbonate. Orthostatic blood pressure response after dialysis did not differ significantly. DISCUSSION: The use of high dialysate bicarbonate compared to low dialysate bicarbonate was associated with hypocalcemia, alkalosis, and a more pronounced hypokalemia. During hemodialysis with UF, a better preservation of blood pressure, stroke volume, and cardiac output may be achieved with low dialysate bicarbonate compared to high dialysate bicarbonate.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.243
Teacher spread0.238 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicRenal function and acid-base balanceFrench-language works237,207