MétaCan
Menu
Back to cohort
Record W4399104511 · doi:10.22488/okstate.24.000036

Numerical investigation of an energy pile-based solar-assisted ground source heat pump system for space heating and cooling

2024· article· en· W4399104511 on OpenAlexaboutno aff
Charaka Beragama Jathunge, Philip Adebayo, Seth B. Dworkin, Aggrey Mwesigye

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEnergy
TopicGeothermal Energy Systems and Applications
Canadian institutionsnot available
Fundersnot available
KeywordsHeat pumpPileEnergy (signal processing)Space (punctuation)Solar energyMechanicsMaterials scienceEnvironmental scienceMechanical engineeringPhysicsComputer scienceGeologyEngineeringGeotechnical engineeringElectrical engineeringHeat exchanger

Abstract

fetched live from OpenAlex

While ground source heat pump systems are a sustainable method to climatize buildings, their long-term performance in cold climates may lead to ground overcooling and, thereby, performance deterioration over time, especially when the loads are significantly imbalanced. Solar-assisted ground source heat pump systems are an alternative to mitigate the ground thermal imbalance by injecting solar thermal energy into the ground to balance energy extraction by the heat pump while also improving the heat pump performance. This study numerically evaluates the performance of a solar-assisted ground source heat pump system for three different climate zones and three modes of operation using a thoroughly validated finite volume-based computational model. A 0.139 m diameter helical steel pile installed to a depth of 18.288 m below the ground was used in this study as the ground heat exchanger. Realistic building load profiles were obtained using OpenStudio for residential applications in Calgary, Toronto, and New York and coupled with a computational fluid dynamics solver to evaluate the overall system performance. The results show that the solar-assisted system shows a significant performance improvement of 16.3% over a non-solar enhanced system for the coldest climatic zone studied. Out of the three system operation modes studied (mode 1: solar loop is turned off at low irradiance, mode 2: solar thermal energy is redirected based on the season, mode 3: solar thermal energy is redirected based on the heat pump operating mode), mode 3 yields the best overall heat pump performance for all the locations (COP: 3.72, 3.74, 4.24 for Calgary, Toronto, and New York, respectively). Interestingly, the results indicate the best-suited system operating mode depends on the degree of dominance of the building's heating load.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.465
Threshold uncertainty score0.971

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.235
Teacher spread0.217 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same topicGeothermal Energy Systems and ApplicationsFrench-language works237,207