MétaCan
Menu
Back to cohort
Record W4399381924 · doi:10.1016/j.nima.2024.169462

Absolute decay counting of 146Sm with <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si2.svg" display="inline" id="d1e953"><mml:mrow><mml:mn>4</mml:mn><mml:mi>π</mml:mi></mml:mrow></mml:math> cryogenic microcalorimetry

2024· article· lv· W4399381924 on OpenAlexafffund
A. Kavner, Quinn R. Shollenberger, Kelly N. Kmak, L. E. Borg, S. T. P. Boyd, John D. Despotopulos, Owen B. Drury, Igor Jovanovic, S. Friedrich, A. T. Gallant, I. Kim, Y. H. Kim, P. Kunz, A. A. Kwiatkowski, Do‐Hoon Kwon, Dongwon Lee, N. D. Scielzo, G. B. Kim

Bibliographic record

VenueNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2024
Typearticle
Languagelv
FieldPhysics and Astronomy
TopicRadioactive Decay and Measurement Techniques
Canadian institutionsTRIUMF
FundersLawrence Livermore National LaboratoryNational Nuclear Security AdministrationInstitute for Basic ScienceOffice of Defense Nuclear NonproliferationTRIUMFU.S. Department of Energy
KeywordsAnalytical Chemistry (journal)Absolute (philosophy)PhysicsDatabaseComputer scienceChemistry

Abstract

fetched live from OpenAlex

We present a methodology for absolute activity counting of long-lived isotopes based on cryogenic Decay Energy Spectroscopy. A 146 Sm source was produced at the TRIUMF Laboratory and then processed and purified at Lawrence Livermore National Laboratory, yielding a pure sample. The source was embedded within a 4 π thermal absorber coupled to a magnetic microcalorimeter achieving nearly 100% counting efficiency. Experimental uncertainties were studied and modeled, including thermal coupling of the source to the absorber, pulse pile-up, trigger, and event selection efficiencies. The absolute activity of the pure 146 Sm source was measured to better than 1% uncertainty.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.314
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentSame topicRadioactive Decay and Measurement TechniquesFrench-language works237,207