MétaCan
Menu
Back to cohort
Record W4399464278 · doi:10.1186/s12903-024-04389-1

Evaluation of masticatory performance and patient satisfaction for conventional and 3D-printed implant overdentures: a randomized crossover study

2024· article· en· W4399464278 on OpenAlexaboutno aff
Mohamed Shady Nabil, Fatma Mahanna

Bibliographic record

VenueBMC Oral Health · 2024
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersMansoura UniversityScience and Technology Development Fund
KeywordsMedicineMasticatory forceOral and maxillofacial surgeryPatient satisfactionDentistryCrossover studyImplantOrthodonticsRandomized controlled trial3d printedSurgeryBiomedical engineering

Abstract

fetched live from OpenAlex

BACKGROUND: This crossover clinical study aimed to evaluate and compare masticatory performance and patient satisfaction for patients rehabilitated with conventional heat-cured acrylic resin and 3D-printed mandibular implant overdentures retained with bar attachment. MATERIALS AND METHODS: Sixteen completely edentulous healthy participants received new conventional dentures. In the mandible, four interforaminal implants were inserted. Following the stage of osseointegration, the bar was constructed in a trapezoidal configuration. Each patient randomly received the following overdentures using a crossover design: (1) conventional heat-cured acrylic resin overdenture and (2) 3D-printed overdenture (developed by scanning of mandibular conventional overdenture). The masticatory performance was assessed by conducting a two-colour mixing ability test at 5, 10, 20, 30, and 50 masticatory cycles. Moreover, the McGill Denture Satisfaction Questionnaire (MDSQ) was employed to assess patient satisfaction. Evaluation was performed after 3 months of using each overdenture. Paired sample t tests were used to compare the masticatory performance and MDSQ scores of patients for both prostheses. RESULTS: No significant difference in masticatory performance was reported between the two types of overdentures. Regarding patient satisfaction, only the esthetic aspect was significantly better for conventionally processed overdentures than for printed overdentures. Insignificant differences were observed regarding other MDSQ items between the two overdentures. CONCLUSION: Within this clinical study, 3D-printed implant overdentures showed promising results in terms of chewing efficiency and patient satisfaction compared to conventionally fabricated implant overdentures. TRIAL REGISTRATION: Retrospectively registered at www. CLINICALTRIALS: gov : NCT06148727.(28/11/2023).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0030.002
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.403
Teacher spread0.337 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueBMC Oral HealthSame topicDental Implant Techniques and OutcomesFrench-language works237,207