MétaCan
Menu
Back to cohort
Record W4399553017 · doi:10.1093/jimb/kuae019

Development of automated metabolite control using mid-infrared probe for bioprocesses and vaccine manufacturing

2024· article· en· W4399553017 on OpenAlexaff
Jennifer Reid, Manjit Haer, A. CHEN, Calvin Adams, Yu Chen Lin, J.F. Cronin, Zhou Yu, Marina Kirkitadze, Tao Yuan

Bibliographic record

VenueJournal of Industrial Microbiology & Biotechnology · 2024
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicViral Infectious Diseases and Gene Expression in Insects
Canadian institutionsSanofi (Canada)
FundersSanofi
KeywordsMetaboliteBiochemical engineeringChemistryBiotechnologyMicrobiologyBiologyBiochemistryEngineering

Abstract

fetched live from OpenAlex

Automation of metabolite control in fermenters is fundamental to develop vaccine manufacturing processes more quickly and robustly. We created an end-to-end process analytical technology and quality by design-focused process by replacing manual control of metabolites during the development of fed-batch bioprocesses with a system that is highly adaptable and automation-enabled. Mid-infrared spectroscopy with an attenuated total reflectance probe in-line, and simple linear regression using the Beer-Lambert Law, were developed to quantitate key metabolites (glucose and glutamate) from spectral data that measured complex media during fermentation. This data was digitally connected to a process information management system, to enable continuous control of feed pumps with proportional-integral-derivative controllers that maintained nutrient levels throughout fed-batch stirred-tank fermenter processes. Continuous metabolite data from mid-infrared spectra of cultures in stirred-tank reactors enabled feedback loops and control of the feed pumps in pharmaceutical development laboratories. This improved process control of nutrient levels by 20-fold and the drug substance yield by an order of magnitude. Furthermore, the method is adaptable to other systems and enables soft sensing, such as the consumption rate of metabolites. The ability to develop quantitative metabolite templates quickly and simply for changing bioprocesses was instrumental for project acceleration and heightened process control and automation. ONE-SENTENCE SUMMARY: Intelligent digital control systems using continuous in-line metabolite data enabled end-to-end automation of fed-batch processes in stirred-tank reactors.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.273
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Industrial Microbiology & BiotechnologySame topicViral Infectious Diseases and Gene Expression in InsectsFrench-language works237,207