MétaCan
Menu
Back to cohort
Record W4399622036 · doi:10.1016/j.ijcard.2024.132264

Outcomes of complete removal versus conservative therapy in cardiac implantable electronic device infections – A systematic review and Meta-analysis

2024· review· en· W4399622036 on OpenAlexaff
Túlio Caldonazo, Johannes Fischer, Alena Spagnolo, Michele Dell'Aquila, Hristo Kirov, Panagiotis Tasoudis, Ricardo Esper Treml, Dominique Vervoort, Michel Pompeu Sá, Torsten Doenst, Mahmoud Diab, Stefan Hagel

Bibliographic record

VenueInternational Journal of Cardiology · 2024
Typereview
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsToronto Rehabilitation InstituteUniversity of Toronto
FundersDeutsche HerzstiftungDeutsche ForschungsgemeinschaftThoracic Surgery FoundationSociety of Thoracic Surgeons
KeywordsMedicineMeta-analysisIntensive care medicineSurgeryInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Complete removal of cardiac implantable electronic devices (CIEDs) is recommended in patients with CIED infections, including both systemic and localized pocket infection. The aim of the study was to provide an up-to-date and comprehensive assessment of evidence relating to the effect of complete CIED extraction in patients with a CIED infection. METHODS: We performed a systematic review and meta-analysis of studies reporting short- and mid-term outcomes in patients who had a device infection or infective endocarditis (IE) and underwent complete removal of the cardiac device (generator and leads) compared to those who received conservative therapy (no removal, partial removal, local antibiotic infiltration or isolated antibiotic therapy). The primary outcome was reinfection/relapse. Secondary outcomes were short-term (30-day/in-hospital) and mid-term (mean follow-up: 43.0 months) mortality. Random effects model was performed. RESULTS: Thirty-two studies met the criteria for inclusion in the final analysis. Patients with complete CIED extraction (n = 905) exhibited a lower rate of relapse/re-infection compared to patients (n = 195) with a conservative treatment approach (n = 195, OR 0.02, 95%CI 0.01-0.06, p < 0.0001, mean-follow-up: 16.1 months). Additionally, these patients displayed a lower short- (OR 0.40, 95%CI 0.23-0.69, p = 0.01) and mid-term (OR 0.52, 95%CI 0.34-0.78, p = 0.002) mortality. CONCLUSIONS: The analysis indicates that patients with a CIED infection who undergo complete CIED extraction exhibit a lower rate of relapse/re-infection. Additionally, a lower short- and mid-term mortality is observed, although it is acknowledged that this outcome may be influenced by treatment allocation bias.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.026
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.018
Threshold uncertainty score0.060

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0110.026
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0180.042
Bibliometrics0.0060.005
Science and technology studies0.0010.001
Scholarly communication0.0030.002
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.165
GPT teacher head0.445
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of CardiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207