MétaCan
Menu
Back to cohort
Record W4399623322 · doi:10.1097/lvt.0000000000000416

Indocyanine green fluorescence quantification during normothermic ex situ perfusion for the assessment of porcine liver grafts after circulatory death

2024· article· en· W4399623322 on OpenAlexafffund
Toru Goto, Yuki Noguchi, Ivan Linares, Laura Mazilescu, Emmanuel Nogueira, Christian Hobeika, Samrat Ray, Catherine Parmentier, Sujani Ganesh, Jathuya Peranantharuban, Harley Chan, Trevor Reichman, Nazia Selzner, Markus Selzner

Bibliographic record

VenueLiver Transplantation · 2024
Typearticle
Languageen
FieldMedicine
TopicOrgan Transplantation Techniques and Outcomes
Canadian institutionsPrincess Margaret Cancer CentreToronto General HospitalUniversity Health Network
FundersJapan Society for the Promotion of ScienceUniversity of TorontoKyoto University Foundation
KeywordsIndocyanine greenMedicineLiver transplantationPerfusionParenchymaArteryPathologyTissue plasminogen activatorTransplantationCardiologySurgeryInternal medicine

Abstract

fetched live from OpenAlex

Current graft evaluation during normothermic ex situ liver perfusion lacks real-time parameters for predicting posttransplant hepatocyte and biliary function. Indocyanine green (ICG) imaging has been widely used in liver surgery, enabling the visualization of hepatic uptake and excretion through bile using near-infrared light. In this research, porcine livers under various ischemic conditions were examined during a 5-hour normothermic ex situ liver perfusion procedure, introducing ICG at 1 hour through the hepatic artery. These conditions included livers from heart-beating donors, donation after circulatory death (DCD) with warm ischemic durations of 60 minutes (DCD60) and 120 minutes (DCD120), as well as interventions utilizing tissue plasminogen activator in DCD120 cases (each n = 5). Distinct hepatic fluorescence patterns correlated with different degrees of ischemic injury ( p = 0.01). Low ICG uptake in the parenchyma (less than 40% of maximum intensity) was more prevalent in DCD120 (21.4%) compared to heart-beating donors (6.2%, p = 0.06) and DCD60 (3.0%, p = 0.02). Moreover, ICG clearance from 60 minutes to 240 minutes was significantly higher in heart-beating donors (69.3%) than in DCD60 (17.5%, p < 0.001) and DCD120 (32.1%, p = 0.01). Furthermore, thrombolytic intervention using tissue plasminogen activator in DCD120 resulted in noteworthy outcomes, including significantly reduced ALP levels ( p = 0.04) and improved ICG clearance ( p = 0.02) with a trend toward mitigating fibrin deposition similar to DCD60, as well as enhancements in bile production ( p = 0.09). In conclusion, ICG fluorescence imaging during normothermic ex situ liver perfusion provides real-time classification of hepatic vascular and biliary injuries, offering valuable insights for the more accurate selection and postintervention evaluation of marginal livers in transplantation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.757
Threshold uncertainty score0.500

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.289
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueLiver TransplantationSame topicOrgan Transplantation Techniques and OutcomesFrench-language works237,207