MétaCan
Menu
Back to cohort
Record W4399727759 · doi:10.3390/prosthesis6030048

Comparison of Socket Geometry, Socket Comfort, and Patient Experience between Manually- and Digitally-Designed Prosthetic Sockets for Lower-Limb Amputees: A Feasibility Study

2024· article· en· W4399727759 on OpenAlexaff
Arezoo Eshraghi, Clara Phillips, Crystal MacKay, Steven Dilkas, Zonsire Riondato, Stefania Lehkyj, Winfried Heim

Bibliographic record

VenueProsthesis · 2024
Typearticle
Languageen
FieldEngineering
TopicProsthetics and Rehabilitation Robotics
Canadian institutionsToronto Rehabilitation InstituteUniversity of TorontoWest Park Healthcare Centre
Fundersnot available
KeywordsComputer scienceEngineering drawingBiomedical engineeringOrthodonticsEngineeringMedicine

Abstract

fetched live from OpenAlex

Prosthetic socket manufacturing is experiencing a revolutionary shift towards using digital methods, such as 3D scanning and 3D printing. However, using digital methods requires the clinician to transfer their skills from making sockets by hand to making sockets with a computer. This shift in practice may change the socket geometry and fit; however, to what extent is unknown. Thus, the aim of this study was to explore the feasibility of analyzing geometric and clinical differences between digitally- and manually-designed sockets. Nine adult inpatients with below-knee amputation were recruited. Two sockets were 3D printed for each participant from 3D socket models that were developed from: (1) 3D scanning a manually-modified hand-casted positive mold of the residuum; and (2) a digitally-modified 3D scan of the residuum. Manual and digital procedures were compared for three measures: final socket geometry, the Socket Comfort Score, and a patient experience survey. Feasibility data were collected to measure protocol implementation fidelity to inform a future larger study. These data revealed that 89% of participants followed the intended protocol, no participants dropped out, and only one adverse event was report. As no significant geometric differences were found and participants experienced similar comfort scores between manually- and digitally-designed sockets, study feasibility was determined to be successful. Thus, a randomized control trial study will be conducted to draw statistically relevant conclusions from these outcome measures that may provide meaningful information for improving digital design procedures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.309
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.320
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueProsthesisSame topicProsthetics and Rehabilitation RoboticsFrench-language works237,207