MétaCan
Menu
Back to cohort

Scaled-up Microfluidic Lung Assist Device for Artificial Placenta Application with High Gas Exchange Capacity

2024· article· en· W4399892561 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueACS Biomaterials Science & Engineering · 2024
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsMcMaster University
FundersCanadian Institutes of Health ResearchCanada Research ChairsOntario Research Foundation
KeywordsArtificial lungMicrofluidicsMaterials scienceBiomedical engineeringNanotechnologyEngineeringBiologyNeuroscience

Abstract

fetched live from OpenAlex

Premature neonates with underdeveloped lungs experience respiratory issues and need respiratory support, such as mechanical ventilation or extracorporeal membrane oxygenation (ECMO). The "artificial placenta" (AP) is a noninvasive approach that supports their lungs and reduces respiratory distress, using a pumpless oxygenator connected to the systemic circulation, and can address some of the morbidity issues associated with ECMO. Over the past decade, microfluidic blood oxygenators have garnered significant interest for their ability to mimic physiological conditions and incorporate innovative biomimetic designs. Achieving sufficient gas transfer at a low enough pressure drop for a pumpless operation without requiring a large volume of blood to prime such an oxygenator has been the main challenge with microfluidic lung assist devices (LAD). In this study, we improved the gas exchange capacity of our microfluidic-based artificial placenta-type LAD while reducing its priming volume by using a modified fabrication process that can accommodate large-area thin film microfluidic blood oxygenator (MBO) fabrication with a very high gas exchange surface. Additionally, we demonstrate the effectiveness of a LAD assembled by using these scaled-up MBOs. The LAD based on our artificial placenta concept effectively increases oxygen saturation levels by 30% at a flow rate of 40 mL/min and a pressure drop of 23 mmHg in room air, which is sufficient to support partial oxygenation for 1 kg preterm neonates in respiratory distress. When the gas ambient environment was changed to pure oxygen at atmospheric pressure, the LAD would be able to support premature neonates weighing up to 2 kg. Furthermore, our experiments reveal that the LAD can handle high blood flow rates of up to 150 mL/min and increase oxygen saturation levels by ∼20%, which is equal to an oxygen transfer of 7.48 mL/min in an enriched oxygen environment and among the highest for microfluidic AP type devices. Such performance makes this LAD suitable for providing essential support to 1-2 kg neonates in respiratory distress.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.106
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.235
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it