MétaCan
Menu
Back to cohort
Record W4400051897 · doi:10.1111/jan.16286

Integrated pulmonary index during procedural sedation and analgesia: A cluster‐randomized trial

2024· article· en· W4400051897 on OpenAlexaffabout
Aaron Conway, Mohammad Goudarzi Rad, Kristina Chang, Matteo Parotto, Sebastian Mafeld

Bibliographic record

VenueJournal of Advanced Nursing · 2024
Typearticle
Languageen
FieldMedicine
TopicHealthcare Technology and Patient Monitoring
Canadian institutionsUniversity of TorontoUniversity Health Network
FundersMedtronic
KeywordsMedicineSedationRandomized controlled trialCapnographyALARMEmergency medicineAnesthesiaPhysical therapyInternal medicine

Abstract

fetched live from OpenAlex

Abstract Aim To evaluate the effectiveness of utilizing the integrated pulmonary index for capnography implementation during sedation administered by nurses. Design Cluster‐randomized trial. Methods Participants were enrolled from the interventional radiology department at an academic hospital in Canada. Nurses were randomized to either enable or disable the Integrated Pulmonary Index feature of the capnography monitor. Procedures were observed by a research assistant to collect information about alarm performance characteristics. The primary outcome was the number of seconds in an alert condition state without an intervention being applied. Results The number of seconds in an alarm state without intervention was higher in the group that enabled the integrated pulmonary index compared to the group that disabled this feature, but this difference did not reach statistical significance. Likewise, the difference between groups for the total alarm duration, total number of alarms and the total number of appropriate alarms was not statistically significant. The number of inappropriate alarms was higher in the group that enabled the Integrated Pulmonary Index, but this estimate was highly imprecise. There was no difference in the odds of an adverse event (measured by the Tracking and Reporting Outcomes of Procedural Sedation tool) occurring between groups. Desaturation events were uncommon and brief in both groups but the area under the SpO 2 90% desaturation curve scores were lower for the group that enabled the integrated pulmonary index. Conclusion Enabling the integrated pulmonary index during nurse‐administered procedural sedation did not reduce nurses' response times to alarms. Therefore, integrating multiple physiological parameters related to respiratory assessment into a single index did not lower the threshold for intervention by nurses. Implications for the Profession and/or Patient Care The time it takes to respond to capnography monitor alarms will not be reduced if the integrated pulmonary Iindex feature of capnography monitors is enabled during nurse‐administered procedural sedation. Impact Results do not support the routine enabling of the integrated pulmonary index when nurses use capnography to monitor patients during procedural sedation as a strategy to reduce the time it takes to initiate responses to alarms. Reporting Method CONSORT. Patient or Public Contribution There was no patient or public contribution. Trial Registration This study was prospectively registered at ClinicalTrials.gov (ID: NCT05068700).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.284
Threshold uncertainty score0.360

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.332
Teacher spread0.317 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Advanced NursingSame topicHealthcare Technology and Patient MonitoringFrench-language works237,207