MétaCan
Menu
Back to cohort
Record W4400066081 · doi:10.14245/ns.2448060.030

The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images

2024· article· en· W4400066081 on OpenAlexaff
Yao‐Wen Liang, Yu-Ting Fang, Ting-Chun Lin, Cheng-Ru Yang, Chih-Chang Chang, Hsuan-Kan Chang, Chin-Chu Ko, Tsung-Hsi Tu, Li-Yu Fay, Jau‐Ching Wu, Hsiang-Wei Hu, You‐Yin Chen, Chao‐Hung Kuo

Bibliographic record

VenueNeurospine · 2024
Typearticle
Languageen
FieldEngineering
TopicMedical Imaging and Analysis
Canadian institutionsArtificial Intelligence in Medicine (Canada)
FundersFood and Drug Administration
KeywordsSegmentationMagnetic resonance imagingComputer scienceLumbarArtificial intelligenceSpinal stenosisLumbar spinal stenosisNeurogenic claudicationResidualRadiologyMedicineComputer visionAlgorithm

Abstract

fetched live from OpenAlex

OBJECTIVE: This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans. METHODS: Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net's segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness. RESULTS: The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements. CONCLUSION: Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.017
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.031

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.017
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0050.002
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0010.001
Research integrity0.0020.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.302
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueNeurospineSame topicMedical Imaging and AnalysisFrench-language works237,207