A Hemoglobinopathy That Produces an Array of Different Hemoglobin A1c Values
Bibliographic record
Abstract
Hemoglobin A1c (HbA1c) refers to non-enzymatically glycated hemoglobin and reflects the patient's glycemic status over approximately 3 months. An elevated HbA1c over 6.5% National Glycohemoglobin Standardization Program (NGSP) (48 mmol/mol the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)) can be used to diagnose diabetes mellitus. In our laboratory, HbA1c is determined by ion-exchange chromatography which has the advantage of detecting common Hb variants such as Hb S, C, E and D without adversely affecting the HbA1c determination. Certain homozygous or compound heterozygous hemoglobinopathies such as homozygous sickle disease and Hb SC disease can significantly lower the HbA1c by reducing red cell lifespan. Occasionally however, rare and mostly benign hemoglobinopathies can interfere with this technique resulting in an apparent elevation of HbA1c in an otherwise non-diabetic patient. In this report, we describe such a hemoglobinopathy termed Hb Wayne that resulted in a significant HbA1c elevation in a normoglycemic individual. HbA1c was determined by multiple methods including immunoassay, a modified capillary electrophoresis and an alternative ion-exchange system. These techniques yielded significantly lower A1c results, more in keeping with the patient's clinical background. The alternative ion-exchange system resulted in a low A1c that was qualified by warning flags on the chromatogram that indicated the result was not reportable. The hemoglobinopathy in question, Hb Wayne, is a frameshift mutation in the alpha globin gene that results in an extended alpha globin polypeptide that can form two variants Hb Wayne I and Wayne II. Hb Wayne is a clinically silent asymptomatic disorder with no hematologic consequences. The artifactual elevation of HbA1c is, in contrast, very significant because it may result in a misdiagnosis of diabetes mellitus leading to unnecessary treatment. In this report, we compare our findings with other descriptions of Hb Wayne in the literature and corroborate a number of previous observations and conclusions.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".