MétaCan
Menu
Back to cohort
Record W4400195152 · doi:10.1097/mat.0000000000002150

Transcatheter Axial Pump Use in Pediatric Patients on Veno-Arterial Extracorporeal Membrane Oxygenation: An ACTION Collaborative Experience

2024· article· en· W4400195152 on OpenAlex
Svetlana Shugh, Sebastian C. Tume, Neha Bansal, John C. Dykes, Jesse J. Esch, Aamir Jeewa, Sabrina Law, Matthew J. O’Connor, John J. Parent, Ahmed S. Said, Frank G. Scholl, Muhammad Shezad, Brian H. Morray

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueASAIO Journal · 2024
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsHospital for Sick Children
Fundersnot available
KeywordsExtracorporeal membrane oxygenationOxygenationMedicineAction (physics)CardiologyInternal medicine

Abstract

fetched live from OpenAlex

We report the largest pediatric multicenter experience with Impella pump use and peripheral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support. Utilizing the Advanced Cardiac Therapies Improving Outcomes Network (ACTION) collaborative database, we conducted a retrospective, multicenter study of all patients with cardiogenic shock requiring VA-ECMO support with subsequent Impella implant between October 2014 and December 2021. The primary outcome was defined as death while on Impella support. Secondary outcomes were recovery, transplantation, and transition to durable ventricular assist device (VAD) at the time of Impella explantation. Adverse events were defined according to the ACTION registry criteria. Twenty subjects were supported with Impella; Impella 2.5 (n = 3), CP (n = 12), 5.0/5.5 (n = 5). The median Interquartile range (IQR) age, weight, and body surface area at implantation were 15.6 years (IQR = 13.9-17.2), 65.7 kg (IQR = 53.1-80.7), and 1.74 m2 (IQR = 1.58-1.98). Primary cardiac diagnoses were dilated cardiomyopathy/myocarditis in nine (45%), congenital heart disease in four (20%), graft failure/rejection in four (20%), and three (15%) others. Most common adverse events included hemolysis (50%) and bleeding (20%). There were two deaths (10%) in the cohort. Nine patients (45%) were explanted for recovery, eight (40%) were transitioned to a durable VAD, and one (5%) underwent heart transplantation. Impella percutaneous pump support should be considered in the older pediatric population supported with peripheral VA-ECMO, as a means of left heart decompression, and a strategy to come off ECMO to achieve endpoints of myocardial recovery, transition to a durable VAD, or transplantation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.594
Threshold uncertainty score0.691

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.265
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it