MétaCan
Menu
Back to cohort
Record W4400325720 · doi:10.1186/s42836-024-00258-y

Inclinometer use in primary total hip arthroplasty does not improve acetabular component positioning: a non-randomized control trial

2024· article· en· W4400325720 on OpenAlexaff
Kyle Goldstein, Wyatt Tyndall, Michaela Nickol, Johannes M. van der Merwe

Bibliographic record

VenueArthroplasty · 2024
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsUniversity of Saskatchewan
Fundersnot available
KeywordsInclinometerRandomized controlled trialArthroplastyMedicineTotal hip arthroplastyComponent (thermodynamics)Hip arthroplastyPhysical therapyPhysical medicine and rehabilitationSurgeryGeodesyGeography

Abstract

fetched live from OpenAlex

INTRODUCTION: Total hip arthroplasty (THA) is a common surgical procedure that aims to relieve pain, improve function, and increase mobility in patients with hip joint pathology. One of the most challenging aspects of THA is to determine the correct angle of the acetabular component's placement. Intraoperative inclinometers have emerged as a promising tool to obtain accurate measurements of the acetabular component's inclination. The primary objective of this study was to evaluate the accuracy and efficacy of using intraoperative inclinometers for THA. METHODS: This non-randomized control trial evaluated patients undergoing primary THA. Patients in the inclinometer group had an inclinometer used intraoperatively to measure acetabular component inclination, and patients in the control group had no inclinometer. Inclination and anteversion of the acetabular component were measured on postoperative radiographs. RESULTS: A total of 223 patients were included in the study. The mean inclination angle of the acetabular cup was significantly higher in the inclinometer group (43.9° vs. 41.5°, P < 0.001). This difference was not clinically significant. There was no significant difference in anteversion. There were no significant differences in the number of patients within the safe zones for inclination or anteversion, or in the number of patients experiencing a dislocation. No correlation was found between inclinometer measurement and measured acetabular component inclination. Inclinometer use and body mass index (BMI) were the sole statistically significant factors in determining acetabular component inclination. CONCLUSIONS: This study indicated no current benefit to inclinometer use during primary THA, as measured by inclination, anteversion, and dislocation rate. However, this might be confounded by subtle variations in patient positioning, which may be a strong area of study in the future.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.040
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.245
Teacher spread0.233 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueArthroplastySame topicOrthopaedic implants and arthroplastyFrench-language works237,207