Stress testing the Centiloid: Precision and variability of PET quantification of amyloid pathology
Bibliographic record
Abstract
INTRODUCTION: Assessing the potential sources of bias and variability of the Centiloid (CL) scale is fundamental for its appropriate clinical application. METHODS: We included 533 participants from AMYloid imaging to Prevent Alzheimer's Disease (AMYPAD DPMS) and Alzheimer's Disease Neuroimaging Initiative (ADNI) cohorts. Thirty-two CL pipelines were created using different combinations of reference region (RR), RR and target types, and quantification spaces. Generalized estimating equations stratified by amyloid positivity were used to assess the impact of the quantification pipeline, radiotracer, age, brain atrophy, and harmonization status on CL. RESULTS: RR selection and RR type impact CL the most, particularly in amyloid-negative individuals. The standard CL pipeline with the whole cerebellum as RR is robust against brain atrophy and differences in image resolution, with 95% confidence intervals below ± 3.95 CL for amyloid beta positivity cutoffs (CL < 24). DISCUSSION: The standard CL pipeline is recommended for most scenarios. Confidence intervals should be considered when operationalizing CL cutoffs in clinical and research settings. HIGHLIGHTS: We developed a framework for evaluating Centiloid (CL) variability to different factors. Reference region selection and delineation had the highest impact on CL values. Whole cerebellum (WCB) and whole cerebellum plus brainstem (WCB+BSTM) as reference regions yielded consistent results across tracers. The standard CL pipeline is robust against atrophy and image resolution variation. Estimated within- and between-pipeline variability (95% confidence interval) in absolute CL units.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.074 | 0.150 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.001 | 0.002 |
| Bibliometrics | 0.002 | 0.001 |
| Science and technology studies | 0.001 | 0.002 |
| Scholarly communication | 0.003 | 0.002 |
| Open science | 0.002 | 0.003 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.002 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".