Per-Phase Unsymmetrical Adaptive Derivative Optimized Droop for Mitigating Voltage Quality Issues of Unbalanced Islanded Microgrids

2024· article· en· W4400410966 on OpenAlexaff
Dalia Yousri, Hany E. Z. Farag, Hatem Zeineldin, Ahmed Al‐Durra, Ehab F. El‐Saadany

Bibliographic record

VenueIEEE Transactions on Sustainable Energy · 2024
Typearticle
Languageen
FieldEngineering
TopicMicrogrid Control and Optimization
Canadian institutionsYork University
FundersAdvanced Technology Research Council
KeywordsVoltage droopMicrogridControl theory (sociology)Controller (irrigation)Benchmark (surveying)VoltageEngineeringInverterVoltage controllerVoltage regulationAC powerThree-phaseNonlinear systemComputer scienceVoltage regulatorControl (management)Electrical engineering

Abstract

fetched live from OpenAlex

The proliferation of unbalanced linear and nonlinear loads in microgrids degrades the voltage quality at the inverter terminals, and thus, load terminals receive unbalanced and distorted voltages. To alleviate these voltage quality issues, this paper proposes a per-phase unsymmetrical adaptive derivative optimized droop control scheme for unbalanced islanded microgrids (UIMG). The proposed controller is coupled with a per-phase unsymmetrical virtual impedance (UVI) to mitigate the unbalance of the inverter-based UIMG. Additionally, a proportional multi-resonant (PMR) controller is adopted to compensate for the voltage distortion. To improve the UIMG dynamics response while changing the loading states, derivative terms of active and reactive powers are added to the proposed control. The derivative gains are adaptively updated with the change in the microgrid loading to achieve the desired transient response. The proposed scheme is formulated as a multi-objective optimization problem to determine the per-phase unsymmetrical droop settings and UVI that fit different loading states simultaneously. Several case studies are designed to test the effectiveness of the proposed control scheme under different types of disturbances and operating conditions. The cases are conducted on the IEEE 34-bus benchmark power distribution feeder with a combination of unbalanced linear and nonlinear loads. Moreover, the proposed control is validated using real-time simulations carried out in OPAL-RT system. The results show that the proposed control scheme is capable of mitigating voltage quality issues by reducing the voltage unbalance factor and voltage distortion.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.979
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.275
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Sustainable EnergySame topicMicrogrid Control and OptimizationFrench-language works237,207