Design and implementation of an innovative single-phase direct AC-AC bipolar voltage buck converter with enhanced control topology
Bibliographic record
Abstract
Direct AC-AC converters are strong candidates in the power converting system to regulate grid voltage against the perturbation in the line voltage and to acquire frequency regulation at discrete step levels in variable speed drivers for industrial systems. All such applications require the inverted and non-inverted form of the input voltage across the output with voltage-regulating capabilities. The required value of the output frequency is gained with the proper arrangement of the number of positive and negative pulses of the input voltage across the output terminals. The period of each such pulse for low-frequency operation is almost the same as the half period of the input grid or utility voltage. These output pulses are generated by converting the positive and negative input half cycles in noninverting and inverting forms as per requirement. There is no control complication to generate control signals used to adjust the load frequency as the operating period of the switching devices is normally greater than the period of the source voltage. However, high-frequency pulse width modulated (PWM) control signals are used to regulate the output voltage. The size of the inductor and capacitor is inversely related to the value of the switching frequency. Similarly, the ripple contents of voltage and currents in these filtering components are also inversely linked with PWM frequency. These constraints motivate the circuit designer to select high PWM frequency. However, the alignment of the high-frequency control input with the variation in the input source voltage is a big challenge for a design engineer as the switching period of a high-frequency signal normally lies in the microsecond. It is also required to operate some high-frequency devices for various half cycles of the source voltage, creating control complications as the polarities of the half cycles are continuously changing. This requires at least the generation of two high-frequency signals for different intervals. The interruption of the filtering inductor current is a big source of high voltage surges in circuits where the high-frequency transistors operate in a complementary way. This may be due to internal defects in the switching transistors or some unnecessary inherent delay in their control signals. In this research work, a simplified AC-AC converter is developed that does not need alignment of high-frequency control with the polarity of the source voltage. With this approach, high-frequency signals can be generated with the help of any analog or digital control system. By applying this technique, only one high-frequency control signal is generated and applied in AC circuits, as in a DC converter, without applying a highly sensitive polarity sensing circuit. So, controlling complications is drastically simplified. The circuit and configuration always avoid the current interruption problem of filtering the inductor. The proposed control and circuit topology are tested both in computer-based simulation and practically developed circuits. The results obtained from these platforms endorse the effectiveness and validation of the proposed work.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.003 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".