MétaCan
Menu
Back to cohort
Record W4401548065 · doi:10.1002/mrm.30225

<scp>RF</scp> shimming in the cervical spinal cord at <scp>7 T</scp>

2024· article· en· W4401548065 on OpenAlexafffund
Daniel S. Papp, Kyle M. Gilbert, Gaspard Cereza, Alexandre D’Astous, Nibardo Lopez Rios, Mathieu Boudreau, Marcus J. Couch, Pedram Yazdanbakhsh, Robert Barry, Eva Alonso‐Ortiz, Julien Cohen‐Adad

Bibliographic record

VenueMagnetic Resonance in Medicine · 2024
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsInstitut Universitaire de Gériatrie de MontréalMcGill UniversityMila - Quebec Artificial Intelligence InstituteMontreal Neurological Institute and HospitalUniversité de MontréalSiemens (Canada)Centre Hospitalier Universitaire Sainte-JustineWestern UniversityPolytechnique Montréal
FundersNational Institute of Biomedical Imaging and BioengineeringFonds de Recherche du Québec - SantéNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchNational Institutes of HealthCanada Foundation for Innovation
KeywordsSpinal cordMagnetic resonance imagingShim (computing)MedicineCoefficient of variationCordNuclear medicineNuclear magnetic resonanceBiomedical engineeringRadiologyChemistryPhysicsSurgery

Abstract

fetched live from OpenAlex

Abstract Purpose Advancing the development of 7 T MRI for spinal cord imaging is crucial for the enhanced diagnosis and monitoring of various neurodegenerative diseases and traumas. However, a significant challenge at this field strength is the transmit field inhomogeneity. Such inhomogeneity is particularly problematic for imaging the small, deep anatomical structures of the cervical spinal cord, as it can cause uneven signal intensity and elevate the local specific absorption ratio, compromising image quality. This multisite study explores several RF shimming techniques in the cervical spinal cord. Methods Data were collected from 5 participants between two 7 T sites with a custom 8Tx/20Rx parallel transmission coil. We explored two radiofrequency (RF) shimming approaches from an MRI vendor and four from an open‐source toolbox, showcasing their ability to enhance transmit field and signal homogeneity along the cervical spinal cord. Results The circularly polarized (CP), coefficient of variation (CoV), and specific absorption rate (SAR) efficiency shim modes showed the highest B1+ efficiency, and the vendor‐based “patient” and “volume” modes showed the lowest B1+ efficiency. The coefficient of variation method produced the highest CSF/spinal cord contrast on T2*‐weighted scans (ratio of 1.27 ± 0.03), and the lowest variation of that contrast along the superior–inferior axis. Conclusion The study's findings highlight the potential of RF shimming to advance 7 T MRI's clinical utility for central nervous system imaging by enabling more homogenous and efficient spinal cord imaging. Additionally, the research incorporates a reproducible Jupyter Notebook, enhancing the study's transparency and facilitating peer verification.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.344
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207