Transjugular Transcatheter Tricuspid Valve Replacement
Bibliographic record
Abstract
BACKGROUND: Data on procedural and early outcomes after transjugular transcatheter tricuspid valve replacement (TTVR) are limited. OBJECTIVES: This study sought to evaluate first-in-man procedural and clinical outcomes after transjugular TTVR with a special focus on patients who received large device sizes in whom TTVR outcomes have been questioned. METHODS: The retrospective registry included patients who underwent TTVR using the LuX-Valve Plus system (Jenscare Biotechnology Co Ltd) for symptomatic tricuspid regurgitation (TR) from January 2022 until February 2024 at 15 international centers in a compassionate use setting. The endpoints were procedural TR reduction, in-hospital death, adverse events, and 1-month survival. We further stratified results according to the size of the implanted device (<55 vs ≥55 mm). RESULTS: The registry included a total of 76 patients at a median age of 78 years (Q1-Q3: 72-83 years, 47.4% women). TR was reduced to ≤2+ and ≤1+ in 94.7% and 90.8% of patients (75.0% of patients received TTVR devices ≥55 mm) with well-sustained results at 1-month follow-up (TR ≤2+ in 95.0% and ≤1+ 86.8%). Residual TR was paravalvular in all cases. In-hospital death occurred in 4 patients (5.3%). Four patients (5.3%) underwent cardiac surgery during index hospitalization. Major in-hospital bleeding events occurred in 5 patients (6.6%). New in-hospital pacemaker implantation was required in 3.9% of patients in the overall cohort (5.7% in "pacemaker-naive" individuals). No cases of valve thrombosis, stroke, myocardial infarction, or pulmonary embolism were observed. At 1-month follow-up, survival was 94.4%, and NYHA functional class significantly improved. One further patient received a pacemaker, 1 further bleeding event occurred, and 2 patients underwent reintervention or surgery within the first 30 days after TTVR. No differences in procedural outcomes or adverse events were observed after stratification for valve size. CONCLUSIONS: Transjugular TTVR appears to be a safe and effective treatment option for patients with severe TR with comparable outcomes in very large tricuspid anatomies.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.069 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".