MétaCan
Menu
Back to cohort
Record W4402171195 · doi:10.2196/59867

Implementation of Artificial Intelligence–Based Diabetic Retinopathy Screening in a Tertiary Care Hospital in Quebec: Prospective Validation Study

2024· article· en· W4402171195 on OpenAlexaffvenueabout
Fares Antaki, I. Hammana, Marie-Catherine Tessier, Andrée Boucher, M Jetté, C. Beauchemin, Karim Hammamji, Ariel Yuhan Ong, Marc‐André Rhéaume, Danny Gauthier, Mona Harissi‐Dagher, Pearse A. Keane, Alfons Pomp

Bibliographic record

VenueJMIR Diabetes · 2024
Typearticle
Languageen
FieldMedicine
TopicRetinal Imaging and Analysis
Canadian institutionsUniversité de MontréalCentre Hospitalier de l’Université de Montréal
Fundersnot available
KeywordsMedicineDiabetic retinopathyFundus (uterus)Diabetes mellitusProspective cohort studyTertiary careOphthalmologyRetinopathyOptometryMacular edemaRetinalInternal medicineEndocrinology

Abstract

fetched live from OpenAlex

BACKGROUND: Diabetic retinopathy (DR) affects about 25% of people with diabetes in Canada. Early detection of DR is essential for preventing vision loss. OBJECTIVE: We evaluated the real-world performance of an artificial intelligence (AI) system that analyzes fundus images for DR screening in a Quebec tertiary care center. METHODS: We prospectively recruited adult patients with diabetes at the Centre hospitalier de l'Université de Montréal (CHUM) in Montreal, Quebec, Canada. Patients underwent dual-pathway screening: first by the Computer Assisted Retinal Analysis (CARA) AI system (index test), then by standard ophthalmological examination (reference standard). We measured the AI system's sensitivity and specificity for detecting referable disease at the patient level, along with its performance for detecting any retinopathy and diabetic macular edema (DME) at the eye level, and potential cost savings. RESULTS: This study included 115 patients. CARA demonstrated a sensitivity of 87.5% (95% CI 71.9-95.0) and specificity of 66.2% (95% CI 54.3-76.3) for detecting referable disease at the patient level. For any retinopathy detection at the eye level, CARA showed 88.2% sensitivity (95% CI 76.6-94.5) and 71.4% specificity (95% CI 63.7-78.1). For DME detection, CARA had 100% sensitivity (95% CI 64.6-100) and 81.9% specificity (95% CI 75.6-86.8). Potential yearly savings from implementing CARA at the CHUM were estimated at CAD $245,635 (US $177,643.23, as of July 26, 2024) considering 5000 patients with diabetes. CONCLUSIONS: Our study indicates that integrating a semiautomated AI system for DR screening demonstrates high sensitivity for detecting referable disease in a real-world setting. This system has the potential to improve screening efficiency and reduce costs at the CHUM, but more work is needed to validate it.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.907
Threshold uncertainty score0.188

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.013
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0020.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.327
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2024
Admission routes3
Has abstractyes

Explore more

Same venueJMIR DiabetesSame topicRetinal Imaging and AnalysisFrench-language works237,207