MétaCan
Menu
Back to cohort
Record W4402333832 · doi:10.1002/cnm.3868

Biomechanical design of a new proximal humerus fracture plate using alternative materials

2024· article· en· W4402333832 on OpenAlex
Sabrina Islam, Mitchell Dembowski, Emil H. Schemitsch, Habiba Bougherara, Z. Shaghayegh Bagheri, Radovan Zdero

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueInternational Journal for Numerical Methods in Biomedical Engineering · 2024
Typearticle
Languageen
FieldMedicine
TopicShoulder Injury and Treatment
Canadian institutionsToronto Rehabilitation InstituteWestern UniversityUniversity Health NetworkVictoria HospitalToronto Metropolitan University
Fundersnot available
KeywordsFracture (geology)HumerusOrthodonticsGeologyStructural engineeringEngineeringGeotechnical engineeringMedicineSurgery

Abstract

fetched live from OpenAlex

Abstract Comminuted proximal humerus fractures are often repaired by metal plates, but potentially still experience bone refracture, bone “stress shielding,” screw perforation, delayed healing, and so forth. This “proof of principle” investigation is the initial step towards the design of a new plate using alternative materials to address some of these problems. Finite element modeling was used to create design graphs for bone stress, plate stress, screw stress, and interfragmentary motion via three different fixations (no, 1, or 2 “kickstand” [KS] screws across the fracture) using a wide range of plate elastic moduli ( E P = 5–200 GPa). Well‐known design optimization criteria were used that could minimize bone, plate, and screw failure (i.e., peak stress < ultimate tensile strength), reduce bone “stress shielding” (i.e., bone stress under the new plate ≥ bone stress for an intact humerus, titanium plate, and/or steel plate “control”), and encourage callus growth leading to early healing (i.e., 0.2 mm ≤ axial interfragmentary motion ≤ 1 mm; shear/axial interfragmentary motion ratio <1.6). The findings suggest that a potentially optimal configuration involves the new plate being manufactured from a material with an E P of 5–41.5 GPa with 1 KS screw; but, using no KS screws would cause immediate bone fracture and 2 KS screws would almost certainly lead to delayed healing. A prototype plate might be fabricated using alternative materials suggested for orthopedics and other industries, like fiber‐metal laminates, fiber‐reinforced polymers, metal foams, pure polymers, shape memory alloys, or 3D‐printed porous metals.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.431
Threshold uncertainty score0.683

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.091
GPT teacher head0.467
Teacher spread0.375 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it