MétaCan
Menu
Back to cohort
Record W4402522695 · doi:10.3390/jcm13185432

Overcoming Access Challenges to Treat Arrhythmias in Patients with Congenital Heart Disease Using Robotic Magnetic-Guided Catheter Ablation

2024· review· en· W4402522695 on OpenAlexaff
Paul Khairy, Katia Dyrda, Blandine Mondésert, Martín Aguilar, Marc Dubuc, Julia Cadrin‐Tourigny, Peter G. Guerra, Alexandre Raymond-Paquin, Léna Rivard, Rafik Tadros, Mario Talajic, Bernard Thibault, Laurent Macle, Denis Roy

Bibliographic record

VenueJournal of Clinical Medicine · 2024
Typereview
Languageen
FieldMedicine
TopicCongenital Heart Disease Studies
Canadian institutionsUniversité de MontréalMontreal Heart Institute
Fundersnot available
KeywordsMedicineCatheter ablationCatheterPopulationAblationHeart diseaseIntensive care medicineCardiologySurgery

Abstract

fetched live from OpenAlex

The prevalence of congenital heart disease (CHD) has surged in recent decades, owing to a substantial reduction in mortality. As individuals with CHD age, they become increasingly susceptible to late complications including arrhythmias. These arrhythmias often arise decades after surgical intervention and significantly impact quality of life, hospitalizations, and mortality. Catheter ablation has gained widespread acceptance as a critical intervention for managing arrhythmias in patients with CHD. However, anatomical and physiological features unique to this population pose challenges to standard manual ablation procedures, potentially impacting safety and efficacy. Robotic magnetic-guided navigation (RMN) has emerged as a technological solution to address these challenges. By utilizing soft and flexible catheters equipped with magnets at their tips, RMN enables robotic steering and orientation of catheters in three-dimensional space. This technology overcomes obstacles such as distorted vascular pathways and complex post-surgical reconstructions to facilitate access to target chambers and improve maneuverability within the heart. In this review, we present an overview of the safety and efficacy evidence for RMN-guided catheter ablation in CHD patients and highlight potential advantages. Additionally, we provide a detailed case presentation illustrating the practical application of RMN technology in this population. Although the literature on RMN-guided ablation in patients with CHD remains limited, it has shown promise in achieving successful outcomes, particularly in cases where manual ablation failed or was deemed non-feasible. Further validation through large-scale prospective studies is necessary to fully ascertain the benefits of RMN technology in this patient population.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.202
GPT teacher head0.472
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Clinical MedicineSame topicCongenital Heart Disease StudiesFrench-language works237,207