Beat-to-Beat Oscillometric Blood Pressure Estimation: A Bayesian Approach With System Identification

2024· article· en· W4402743549 on OpenAlexaff
Ramin Farzam, Mohammad Hasan Azad, Hamid Abrishami Moghaddam, Mohamad Forouzanfar

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2024
Typearticle
Languageen
FieldEngineering
TopicNon-Invasive Vital Sign Monitoring
Canadian institutionsÉcole de Technologie Supérieure
Fundersnot available
KeywordsBeat (acoustics)Blood pressureComputer scienceBayesian probabilitySpeech recognitionArtificial intelligenceAcousticsMedicineInternal medicinePhysics

Abstract

fetched live from OpenAlex

OBJECTIVE: Our study aims to advance noninvasive blood pressure (BP) monitoring through the introduction of innovative beat-to-beat oscillometric BP estimation methods. We aim to overcome current device limitations by delivering continuous and accurate BP estimates, utilizing physiologically based mathematical models. METHODS: We developed novel beat-to-beat oscillometric BP estimation methods based on physiologically grounded mathematical models of intra-arterial BP and the arterial system effect. Our approach includes a recursive Bayesian method for parameter estimation and a new system identification technique to refine initial parameter estimates. We tested our methods through simulations and real-world experiments involving 10 individuals. RESULTS: Mean errors for systolic and diastolic BP were as low as -1.26 mmHg and 2.03 mmHg, respectively, with standard deviations of errors at 5.95 mmHg and 4.16 mmHg. Furthermore, our methods enabled the estimation of additional cardiovascular parameters such as heart rate, respiration rate, and mean arterial pressure. CONCLUSION: Our novel beat-to-beat oscillometric BP estimation methods offer a significant advancement in noninvasive BP monitoring technology, addressing the limitations of current devices by providing continuous beat-to-beat BP estimates. SIGNIFICANCE: Our approach represents a promising direction for improving the reliability and comprehensiveness of cardiovascular parameter estimation in noninvasive BP monitoring devices, facilitating more effective patient care and monitoring.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.975
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.003
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.194
Teacher spread0.189 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicNon-Invasive Vital Sign MonitoringFrench-language works237,207