MétaCan
Menu
Back to cohort

P.287: Novel fast cold flushing cannulation for transplant organ procurement.

2024· article· en· W4402796813 on OpenAlexaffabout
Erica Ladham, Brianna Luo, Yigang Luo

Bibliographic record

VenueTransplantation · 2024
Typearticle
Languageen
FieldMedicine
TopicOrgan Transplantation Techniques and Outcomes
Canadian institutionsMcGill UniversityUniversity of Saskatchewan
Fundersnot available
KeywordsFlushingOrgan procurementMedicineProcurementSurgeryBusinessTransplantation

Abstract

fetched live from OpenAlex

Introduction: A reliable and fast cannulation of aorta in organ procurement for transplantation, is critical, especially for DCD (donation after circulatory death). By shortening warm ischemia time, a better donor organ quality is expected against delay graft function (DGF up to 60%) and primary non-function (PNF, up to 5%) in post transplant recipients of DCD organs. Present study used an in vitro simulate set-up to test the concept of a novel reliable and fast cold flushing cannulation for transplant organ procurement. Method: a 1/2“ ArgyleTM Penrose Tubing 20cm long was used to simulate the abdominal aorta with 4 side holes simulating as celiac artery, superior mesentery artery and bilateral renal arteries, while a PHYCON (I.D. 7.0mm, O.D. 10.7/12.5mm ORAL) endotracheal tube was used as a double balloon cannula in study group(Fig 1), and a traditional MAQUET 21 Fr cannula was used in control group(Fig 2).In the study group, we inserted the double balloon cannula into the simulate abdominal aorta, inflated both balloons, began flushing for 3 minutes. The fluid flowed out of the simulate aorta side holes was recorded. In the control group, a traditional cannula was inserted into the simulate abdominal aorta, a clamp was placed superiorly above the all side holes, and a hand tie was placed distal to the side holes to hold the cannula in place, Similarly flushing was carried out for 3 minutes and flow volume was recorded. In both groups the tests were performed for 10 times. Results: The results shew that the mean time to the start of flushing was 49.6 seconds in the study group and 61.3 seconds in the control group(P=0.007). The results also shew insignificant differences in flow rates between the control group vs study group (620.5ml vs 575ml), P =4.1). Statistic analysis was performed with anova. Conclusion: This study proved that a double-balloon cannula might in fact reliably lessen the warm ischemia time, especially when we took into account of time saved in exposing and clamping the upper abdominal aorta. College of Medicine, University of Saskatchewan in support of the summer student research project.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.302
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueTransplantationSame topicOrgan Transplantation Techniques and OutcomesFrench-language works237,207