Selection of DNA aptamers for detecting metronidazole and ibuprofen: two common additives in soft drinks
Bibliographic record
Abstract
values measured using isothermal titration calorimetry (ITC) were 17.0 μM and 66.7 μM for these two aptamers, respectively. Selectivity experiments indicate that MNZ-1 demonstrates very weak binding to structurally similar drugs, whereas IBF-1 exhibits binding capability to some structurally similar compounds comparable to ibuprofen, enabling the simultaneous detection of these types of drugs. Neither MNZ-1 nor IBF-1 binds to other common drugs. Using ThT, a label-free fluorescent detection method was developed for metronidazole and ibuprofen in soft drinks, showing limits of detection (LODs) of 0.6 μM and 4.7 μM, respectively. Owing to their small size and well-defined secondary structures, these aptamers are expected to be utilized in analytical applications for food and environmental monitoring.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".