MétaCan
Menu
Back to cohort
Record W4403117324 · doi:10.1016/j.jcct.2024.09.011

Reproducibility of myocardial extracellular volume quantification using dual-energy computed tomography in patients with cardiac amyloidosis

2024· article· en· W4403117324 on OpenAlexaff
Yoshito Kadoya, Mehmet Onur Omaygenç, Benjamin J.W. Chow, Gary R. Small

Bibliographic record

VenueJournal of cardiovascular computed tomography · 2024
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsUniversity of Ottawa
FundersPfizer
KeywordsMedicineReproducibilityCardiac amyloidosisComputed tomographyRadiologyDual energyTomographyNuclear medicineExtracellular fluidAmyloidosisCardiologyInternal medicineExtracellularChromatography

Abstract

fetched live from OpenAlex

Background Quantifying myocardial extracellular volume (ECV) using computed tomography (CT) has been shown to be useful in the evaluation of cardiac amyloidosis. However, the reproducibility of CT measurements for myocardial ECV, is not well-established in patients with proven cardiac amyloidosis. Methods This prospective single-center study enrolled cardiac amyloidosis patients to undergo dual-energy CT for myocardial fibrosis assessment. Delayed imaging at 7 and 8 ​min post-contrast and independent evaluations by two blinded cardiologists were performed for ECV quantification using 16-segment (ECV global ) and septal sampling (ECV septal ). Inter- and intraobserver variability and test-retest reliability were measured using Spearman's rank correlation, Bland-Altman analysis, and intraclass correlation coefficients (ICC). Results Among the 24 participants (median age ​= ​78, 67 ​% male), CT ECV global and ECV septal showed median values of 53.6 ​% and 49.1 ​% at 7 ​min, and 53.3 ​% and 50.1 ​% at 8 ​min, respectively. Inter- and intraobserver variability and test-retest reliability for CT ECV global (ICC ​= ​0.798, 0.912, and 0.894, respectively) and ECV septal (ICC ​= ​0.791, 0.898, and 0.852, respectively) indicated good reproducibility, with no evidence of systemic bias between observers or scans. Conclusions Dual-energy CT-derived ECV measurements demonstrated good reproducibility in patients with proven cardiac amyloidosis, suggesting potential utility as a repeatable imaging biomarker for this disease.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.017
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.032

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.017
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.194
Teacher spread0.186 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJournal of cardiovascular computed tomographySame topicAdvanced X-ray and CT ImagingFrench-language works237,207