Comparison of Diffusion-Weighted MRI Using Single-Shot Echo-Planar Imaging and Split Acquisition of Fast Spin-Echo Signal Imaging, a Non-EPI Technique, in Tumors of the Head and Neck
Bibliographic record
Abstract
ABSTRACT BACKGROUND AND PURPOSE: Diffusion-weighted imaging (DWI) using single-shot echo planar imaging (DW-EPI) is susceptible to distortions around air-filled cavities and dental fillings, typical for the head and neck area. Non-EPI, Split acquisition of fast spin echo signals for diffusion imaging (DWSPLICE) could reduce these distortions and enhance image quality, thereby potentially improving recurrence assessment in squamous cell carcinoma (SCC) of the head and neck region. This study evaluated whether DW-SPLICE is a viable alternative to DW-EPI through quantitative and qualitative analyses. MATERIALS AND METHODS: The DW-SPLICE sequence was incorporated into the standard 3.0T head and neck MRI protocol with DW-EPI. Retrospective analysis was conducted on two subgroups: firstly benign or malignant lesions, and secondly post-treatment SCC recurrence. In both subgroups Image quality and distortion were scored by two independent radiologists, blinded for DW-technique, and evaluated using mixed-effect linear models. Lesion apparent diffusion coefficient (ADC) values were assessed with inter-class correlation (ICC) and Bland-Altman analyses. DWI’s delineation geometric similarity to T1-weighted post-contrast (T1Wc) MRI was evaluated using the Dice Similarity Coefficient (DSC) before and after registration. Recurrence in post-treatment SCC scans was evaluated by the same two radiologists blinded for DW-technique. Recurrence detection rates were then compared between DW-SPLICE and DW-EPI using mixed logistic regression at six months and at one-year post-scan follow-up data. RESULTS: From August 2020 to January 2022, 55 benign or malignant lesion scans (55 patients) and 74 post-treatment SCC scans (66 patients) were analyzed. DW-SPLICE scored better on image quality and showed less overall distortion than DW-EPI (0.04 CONCLUSIONS: DW-SPLICE surpasses DW-EPI on image distortion and quality and improves diagnostic reliability for detecting recurrent or residual SCC on 3T MRI of the HN. Consistent use of one method for follow-up is advised, as ADC values are not completely interchangeable. Integrating DW-SPLICE can significantly improve tumor assessments in clinical practice. ABBREVIATIONS: ANTs = Advanced Normalization Tools; DSC = Dice Similarity Coefficient; DW-EPI = Diffusion-weighted single-shot echo planar imaging; DW-MS-EPI = Diffusion-weighted multi-shot echo planar imaging; DW-SPLICE = Diffusion-weighted split acquisition of fast spin echo signals for diffusion imaging; DW-TSE = Diffusion-weighted Turbo Spin Echo; ICC = Intraclass Correlation Coefficient; ROC = Receiver Operating Characteristic; SCC = Squamous cell carcinoma; T1WIc = T1 weighted imaging with gadolinium contrast.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.003 | 0.005 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".