The amenability of different solvents to electrospray ionization mass spectrometry
Bibliographic record
Abstract
Electrospray ionization mass spectrometry is capable of transferring ions from solution to the gas phase across a broad range of solvents. A systematic investigation of the relative performance of different solvents has not been previously conducted, and we sought to remedy this situation. Fourteen solvents across a wide range of polarities were investigated for their ability to provide strong signals for four permanently charged ions. We found the best solvents to be acetone, acetonitrile, dichloromethane, tetrahydrofuran, and the previously unused (in an ESI-MS context) trifluorotoluene. • 14 solvents were tested for their ability to provide ESI-MS signals • 2 permanently charged ions were investigated in both ion modes • Solvents above a certain polarity were capable of providing intense signals • Best solvents were acetone, acetonitrile, dichloromethane, tetrahydrofuran • Trifluorotoluene is a promising new ESI-MS solvent
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.003 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".