MétaCan
Menu
Back to cohort
Record W4403544053 · doi:10.1128/spectrum.00672-24

Evaluation of a near-patient SARS-CoV-2 novel rapid diagnostic platform

2024· article· en· W4403544053 on OpenAlexaff
Johannes C. Botha, Karen Zafilaza, Cathia Soulié, Nicolas Yin, Moira Spyer, Sofia Balaska, S. Chatziioannidou, George Papadakis, Lemonia Skoura, Alexandros Zafiropoulos, George Sourvinos, Olivier Vandenberg, Anne‐Geneviève Marcelin, Electra Gizeli, Eleni Nastouli

Bibliographic record

VenueMicrobiology Spectrum · 2024
Typearticle
Languageen
FieldEngineering
TopicBiosensors and Analytical Detection
Canadian institutionsInstitute of Infection and Immunity
FundersHorizon 2020 Framework Programme
KeywordsPoint-of-care testingPebbleDiagnostic testLoop-mediated isothermal amplificationSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)Point of careMedicineTurnaround timeComputational biologyCoronavirus disease 2019 (COVID-19)Computer sciencePathologyBiologyEmergency medicine

Abstract

fetched live from OpenAlex

The goal of this study is to test a novel device and methodology based on the "Pebble" platform and real-time quantitative colorimetric loop-mediated isothermal amplification (qcLAMP) during SARS-CoV-2 detection using crude samples and extracted RNA. The new method employs an inexpensive lightweight device aimed toward rapid point-of-care testing. An extensive evaluation was performed consisting of 1,693 clinical samples across five independent clinical testing centers. Positive colorimetric results were observed within 20 minutes of testing. At a 20-minute time-to-positive cut-off, the specificity is 98.5% with a diagnostic accuracy of 91.9%, compared to qPCR assays. Our findings indicate that the SARS-CoV-2 qcLAMP diagnostic assay in conjunction with the Pebble device is ideal for point-of-care/near-patient testing.IMPORTANCEHere, we describe our analyses and validation of a novel real-time quantitative colorimetric loop-mediated isothermal amplification (qcLAMP) device, available under the name "Pebble" and associated SARS-CoV-2 diagnostic qcLAMP assay for clinical diagnostic use. The analyses were performed in five independent testing sites across Europe using clinical samples from the associated clinical sites and support the use of "pebble" and associated kit in the diagnostic environment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.202
Threshold uncertainty score0.410

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.245
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueMicrobiology SpectrumSame topicBiosensors and Analytical DetectionFrench-language works237,207