MétaCan
Menu
Back to cohort
Record W4403568078 · doi:10.1177/08465371241291699

Opportunistic Identification of Coronary Artery Calcium and Valve/Vascular Calcifications on Chest X-Ray: Improvements With Single-ExposureDual-Energy Imaging

2024· article· en· W4403568078 on OpenAlexaff
Patrik Rogalla, Jônatas Fávero Prietto dos Santos, Bernd J. Wintersperger, Jay Potipcoe, Steven Tilley, Neda Afkhami, Karim S. Karim, S. Carey, Farah Cadour, Felipe Sánchez Tijmes

Bibliographic record

VenueCanadian Association of Radiologists Journal · 2024
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsMedicineRadiologyCoronary artery diseaseConfidence intervalCalcificationNuclear medicineCardiologyInternal medicine

Abstract

fetched live from OpenAlex

Purpose: To evaluate whether single-exposure, dual-energy chest X-ray (DEX) improves visualization of coronary artery calcium (CAC) and valve/vascular calcifications compared to conventional X-ray. Materials and Methods: Sixty-one bone-marrow transplant patients (22- 79 years; median 61; IQR 15; w/m, 24/37), underwent single-exposure dual-energy X-ray (Reveal 35C, KA imaging) in pa and lateral projection, followed by a standard-of-care chest CT. Two DEX pairs (pa/lateral) were calculated: a composite image (COMP) and a bone image with soft-tissue subtraction (BI). The COMP pair was reviewed by 2 chest radiologists, assessing the presence/absence of CAC and valve/vascular calcifications on a confidence scale from −2 (confidently not present) to 2 (confidently present). Subsequently, the BI pair was revealed, and readers reevaluated both pairs (COMP and BI) jointly using the identical scale. CTCAC scores were categorized according to the CAC-DRS (0-3) and served as standard of reference, valve/vascular calcifications were categorized on CT as present or absent. Results: For detecting CAC on DEX in any CAC-DRS category (1-3), in category 2-3, in category 3, and for valve/vascular calcifications, the ROC-AUC (combined for both readers) for COMP images was 0.74 (CI: 0.64-0.84), 0.81 (CI: 0.68-0.94), 0.84 (CI: 0.69-0.98), and 0.90 (CI: 0.83-0.99), and for the BI images 0.91 (CI: 0.83-0.98), 0.94 (CI: 0.86- 1.00), 0.89 (CI: 0.77-1.00), and 0.98 (CI: 0.96-1.00), with P = .0003, P = .044, P = .42, and P = .55, respectively. The Intraclass-Correlation-Coefficient (ICC) for CAC on COMP/BI was 0.973/0.954, and for valve/vascular calcifications 0.971/0.965. Conclusion: Single-exposure, dual-energy acquisition improves diagnostic confidence for coronary artery calcium and valve/vascular calcification identification on chest X-rays.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.219
Teacher spread0.207 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueCanadian Association of Radiologists JournalSame topicAdvanced X-ray and CT ImagingFrench-language works237,207