MétaCan
Menu
Back to cohort
Record W4403591794 · doi:10.7326/annals-24-00981

Artificial Intelligence–Assisted Colonoscopy for Polyp Detection

2024· review· en· W4403591794 on OpenAlexaff
Saeed Soleymanjahi, Jack Huebner, Lina Elmansy, Niroop Rajashekar, Nando Lüdtke, Rumzah Paracha, Rachel Thompson, Alyssa Grimshaw, Farid Foroutan, Shahnaz Sultan, Dennis Shung

Bibliographic record

VenueAnnals of Internal Medicine · 2024
Typereview
Languageen
FieldMedicine
TopicColorectal Cancer Screening and Detection
Canadian institutionsMcMaster University
Fundersnot available
KeywordsMedicineColonoscopyEndoscopyGeneral surgeryInternal medicineGastroenterologyColorectal cancerCancer

Abstract

fetched live from OpenAlex

BACKGROUND: Randomized clinical trials (RCTs) of computer-aided detection (CADe) system-enhanced colonoscopy compared with conventional colonoscopy suggest increased adenoma detection rate (ADR) and decreased adenoma miss rate (AMR), but the effect on detection of advanced colorectal neoplasia (ACN) is unclear. PURPOSE: To conduct a systematic review to compare performance of CADe-enhanced and conventional colonoscopy. DATA SOURCES: Cochrane Library, Google Scholar, Ovid EMBASE, Ovid MEDLINE, PubMed, Scopus, and Web of Science Core Collection databases were searched through February 2024. STUDY SELECTION: Published RCTs comparing CADe-enhanced and conventional colonoscopy. DATA EXTRACTION: Average adenoma per colonoscopy (APC) and ACN per colonoscopy were primary outcomes. Adenoma detection rate, AMR, and ACN detection rate (ACN DR) were secondary outcomes. Balancing outcomes included withdrawal time and resection of nonneoplastic polyps (NNPs). Subgroup analyses were done by neural network architecture. DATA SYNTHESIS: Forty-four RCTs with 36 201 cases were included. Computer-aided detection-enhanced colonoscopies have higher average APC (12 090 of 12 279 [0.98] vs. 9690 of 12 292 [0.78], incidence rate difference [IRD] = 0.22 [95% CI, 0.16 to 0.28]) and higher ADR (7098 of 16 253 [44.7%] vs. 5825 of 15 855 [36.7%], rate ratio [RR] = 1.21 [CI, 1.15 to 1.28]). Average ACN per colonoscopy was similar (1512 of 9296 [0.16] vs. 1392 of 9121 [0.15], IRD = 0.01 [CI, -0.01 to 0.02]), but ACN DR was higher with CADe system use (1260 of 9899 [12.7%] vs. 1119 of 9746 [11.5%], RR = 1.16 [CI, 1.02 to 1.32]). Using CADe systems resulted in resection of almost 2 extra NNPs per 10 colonoscopies and longer total withdrawal time (0.53 minutes [CI, 0.30 to 0.77]). LIMITATION: Statistically significant heterogeneity in quality and sample size and inability to blind endoscopists to the intervention in included studies may affect the performance estimates. CONCLUSION: Computer-aided detection-enhanced colonoscopies have increased APC and detection rate but no difference in ACN per colonoscopy and a small increase in ACN DR. There is minimal increase in procedure time and no difference in performance across neural network architectures. PRIMARY FUNDING SOURCE: None. (PROSPERO: CRD42023422835).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.028
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.006
Threshold uncertainty score0.030

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.028
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0030.004
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.235
GPT teacher head0.473
Teacher spread0.238 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations83
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueAnnals of Internal MedicineSame topicColorectal Cancer Screening and DetectionFrench-language works237,207