MétaCan
Menu
Back to cohort
Record W4403684294 · doi:10.1097/rlu.0000000000005526

Fully Automated Region-Specific Human-Perceptive-Equivalent Image Quality Assessment: Application to 18F-FDG PET Scans

2024· article· en· W4403684294 on OpenAlexaff
Mehdi Amini, Yazdan Salimi, Ghasem Hajianfar, Ismini Mainta, Elsa Hervier, Amirhossein Sanaat, Arman Rahmim, Isaac Shiri, Habib Zaidi

Bibliographic record

VenueClinical Nuclear Medicine · 2024
Typearticle
Languageen
FieldMedicine
TopicRadiomics and Machine Learning in Medical Imaging
Canadian institutionsUniversity of British Columbia
FundersHôpitaux Universitaires de GenèveSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungNational Science Foundation
KeywordsMedicineImage qualityArtificial intelligenceNuclear medicineQuality assuranceRadiologyPattern recognition (psychology)Computer scienceImage (mathematics)Pathology

Abstract

fetched live from OpenAlex

INTRODUCTION: We propose a fully automated framework to conduct a region-wise image quality assessment (IQA) on whole-body 18 F-FDG PET scans. This framework (1) can be valuable in daily clinical image acquisition procedures to instantly recognize low-quality scans for potential rescanning and/or image reconstruction, and (2) can make a significant impact in dataset collection for the development of artificial intelligence-driven 18 F-FDG PET analysis models by rejecting low-quality images and those presenting with artifacts, toward building clean datasets. PATIENTS AND METHODS: Two experienced nuclear medicine physicians separately evaluated the quality of 174 18 F-FDG PET images from 87 patients, for each body region, based on a 5-point Likert scale. The body regisons included the following: (1) the head and neck, including the brain, (2) the chest, (3) the chest-abdomen interval (diaphragmatic region), (4) the abdomen, and (5) the pelvis. Intrareader and interreader reproducibility of the quality scores were calculated using 39 randomly selected scans from the dataset. Utilizing a binarized classification, images were dichotomized into low-quality versus high-quality for physician quality scores ≤3 versus >3, respectively. Inputting the 18 F-FDG PET/CT scans, our proposed fully automated framework applies 2 deep learning (DL) models on CT images to perform region identification and whole-body contour extraction (excluding extremities), then classifies PET regions as low and high quality. For classification, 2 mainstream artificial intelligence-driven approaches, including machine learning (ML) from radiomic features and DL, were investigated. All models were trained and evaluated on scores attributed by each physician, and the average of the scores reported. DL and radiomics-ML models were evaluated on the same test dataset. The performance evaluation was carried out on the same test dataset for radiomics-ML and DL models using the area under the curve, accuracy, sensitivity, and specificity and compared using the Delong test with P values <0.05 regarded as statistically significant. RESULTS: In the head and neck, chest, chest-abdomen interval, abdomen, and pelvis regions, the best models achieved area under the curve, accuracy, sensitivity, and specificity of [0.97, 0.95, 0.96, and 0.95], [0.85, 0.82, 0.87, and 0.76], [0.83, 0.76, 0.68, and 0.80], [0.73, 0.72, 0.64, and 0.77], and [0.72, 0.68, 0.70, and 0.67], respectively. In all regions, models revealed highest performance, when developed on the quality scores with higher intrareader reproducibility. Comparison of DL and radiomics-ML models did not show any statistically significant differences, though DL models showed overall improved trends. CONCLUSIONS: We developed a fully automated and human-perceptive equivalent model to conduct region-wise IQA over 18 F-FDG PET images. Our analysis emphasizes the necessity of developing separate models for body regions and performing data annotation based on multiple experts' consensus in IQA studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesInsufficient payload (model declined to judge)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.265
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.002
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.081
GPT teacher head0.484
Teacher spread0.403 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueClinical Nuclear MedicineSame topicRadiomics and Machine Learning in Medical ImagingFrench-language works237,207