MétaCan
Menu
Back to cohort
Record W4403857329 · doi:10.1088/1361-6560/ad8c96

Proton bunch monitors for the clinical translation of prompt gamma-ray timing

2024· article· en· W4403857329 on OpenAlexaff
Krystsina Makarevich, Sonja M. Schellhammer, G. Pausch, K. Römer, Jessica Tiebel, J. Turko, A. Wagner, T. Kögler

Bibliographic record

VenuePhysics in Medicine and Biology · 2024
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsInstitute of Particle Physics
Fundersnot available
KeywordsProtonTranslation (biology)Gamma rayPhysicsComputer scienceMedical physicsNuclear physicsNuclear medicineMedicineChemistry

Abstract

fetched live from OpenAlex

Abstract Objective. Prompt gamma-ray timing is an emerging technology in the field of particle therapy treatment verification. This system measures the arrival times of gamma rays produced in the patient body and uses the cyclotron radio frequency signal as time reference for the beam micro-bunches. Its translation into clinical practice is currently hindered by observed instabilities in the phase relation between the cyclotron radio frequency and the measured arrival time of prompt gamma rays. To counteract this, two proton bunch monitors are presented, integrated into the prompt gamma-ray timing workflow and evaluated. Approach. The two monitors are (a) a diamond detector placed at the beam energy degrader, and (b) a cyclotron monitor signal measuring the phase difference between dee current and voltage. First, the two proton bunch monitors as well as their mutual correlation were characterized. Then, a prompt gamma-ray timing measurement was performed aiming to quantify the present magnitude of the phase instabilities and to evaluate the ability of the proton bunch monitors to correct for these instabilities. Main results. It was found that the two new monitors showed a very high correlation for intermediate proton energies after the first second of irradiation, and that they were able to reduce fluctuations in the detected phase of prompt gamma rays. Furthermore, the amplitude of the phase instabilities had intrinsically decreased from about 700 ps to below 100 ps due to cyclotron upgrades. Significance. The uncertainty of the prompt gamma-ray timing method for proton treatment verification was reduced. For routine clinical application, challenges remain in accounting for detector load effects, temperature drifts and throughput limitations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.007
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.442
GPT teacher head0.517
Teacher spread0.075 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicRadiation Therapy and DosimetryFrench-language works237,207