MétaCan
Menu
Back to cohort
Record W4403895353 · doi:10.3390/s24216963

Photoacoustic Resonators for Non-Invasive Blood Glucose Detection Through Photoacoustic Spectroscopy: A Systematic Review

2024· review· en· W4403895353 on OpenAlexaff
Md Rejvi Kaysir, Thasin Mohammad Zaman, Shazzad Rassel, Dayan Ban

Bibliographic record

VenueSensors · 2024
Typereview
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsPhotoacoustic imaging in biomedicinePhotoacoustic spectroscopyGlycemicBlood glucose monitoringMedicineDiabetes mellitusBiomedical engineeringMaterials scienceNanotechnologyComputer scienceOpticsPhysics

Abstract

fetched live from OpenAlex

Diabetes mellitus is a prevalent disease with a rapidly increasing incidence projected worldwide, affecting both industrialized and developing regions. Effective diabetes management requires precise therapeutic strategies, primarily through self-monitoring of blood glucose levels to achieve tight glycemic control, thereby mitigating the risk of severe complications. In recent years, there have been significant advancements in non-invasive techniques for measuring blood glucose using photoacoustic spectroscopy (PAS), as it shows great promise for the detection of glucose using the infrared region (e.g., MIR and NIR) of light. A critical aspect of this method is the detection of the photoacoustic signal generated from blood glucose, which needs to be amplified through a photoacoustic resonator (PAR). In this work, an overview of various types of PARs used for non-invasive glucose sensing is reviewed, highlighting their operating principle, design requirements, limitations, and potential improvements needed to enhance the analysis of photoacoustic signals. The motivation behind this review is to identify and discuss main parameters crucial to the efficient design of PARs used in non-invasive glucose detection, which will be helpful for furthering the basic understanding of this technology and achieving the highly sensitive PAR required for non-invasive glucose monitoring.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesMeta-epidemiology (narrow)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.111
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0050.002
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.278
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueSensorsSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207