MétaCan
Menu
Back to cohort
Record W4403922941 · doi:10.1002/marc.202400418

Highly Conducting and Ultra‐Stretchable Wearable Ionic Liquid‐Free Transducer for Wireless Monitoring of Physical Motions

2024· article· en· W4403922941 on OpenAlexaff
Nicolas R. Tanguy, Araz Rajabi‐Abhari, Eric Williams‐Linera, Nicole Tratnik, Xiao Zhang, Hao Cheng, Alvin Virya, Ning Yan, Ronan Le Lagadec

Bibliographic record

VenueMacromolecular Rapid Communications · 2024
Typearticle
Languageen
FieldEngineering
TopicAdvanced Sensor and Energy Harvesting Materials
Canadian institutionsUniversity of Toronto
FundersDirección General de Asuntos del Personal Académico, Universidad Nacional Autónoma de México
KeywordsElastomerMaterials scienceWearable computerBiomedical engineeringTransducerComputer scienceComposite materialAcousticsMedicineEmbedded system

Abstract

fetched live from OpenAlex

Abstract Wearable strain transducers are poised to transform the field of healthcare owing to the promise of personalized devices capable of real‐time collection of human physiological health indicators. For instance, monitoring patients' progress following injury and/or surgery during physiotherapy is crucial but rarely performed outside clinics. Herein, multifunctional liquid‐free ionic elastomers are designed through the volume effect and the formation of dynamic hydrogen bond networks between polyvinyl alcohol (PVA) and weak acids (phosphoric acid, phytic acid, formic acid, citric acid). An ultra‐stretchable (4600% strain), highly conducting (10 mS cm −1 ), self‐repairable (77% of initial strain), and adhesive ionic elastomer is obtained at high loadings of phytic acid (4:1 weight to PVA). Moreover, the elastomer displayed durable performances, with intact mechanical properties after a year of storage. The elastomer is used as a transducer to monitor human motions in a device comprising an ESP32‐based development board. The device detected walking and/or running biomechanics and communicated motion‐sensing data (i.e., amplitude, frequency) wirelessly. The reported technology can also be applied to other body parts to monitor recovery after injury and/or surgery and inform practitioners of motion biomechanics remotely and in real time to increase convalescence effectiveness, reduce clinic appointments, and prevent injuries.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.025
Threshold uncertainty score0.679

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.273
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueMacromolecular Rapid CommunicationsSame topicAdvanced Sensor and Energy Harvesting MaterialsFrench-language works237,207