MétaCan
Menu
Back to cohort
Record W4403978269 · doi:10.18699/ssmj20240514

On the setting up of numerical modeling of heart valve prostheses

2024· article· en· W4403978269 on OpenAlexaboutno aff
K. Yu. Klyshnikov, P. S. Onishchenko, Т. В. Глушкова, T. N. Akentyeva, A. E. Kostyunin, М. А. Резвова, Е. А. Овчаренко

Bibliographic record

VenueСибирский научный медицинский журнал · 2024
Typearticle
Languageen
FieldEngineering
TopicHydraulic and Pneumatic Systems
Canadian institutionsnot available
Fundersnot available
KeywordsHeart valveCardiologyInternal medicineMedicineComputer science

Abstract

fetched live from OpenAlex

The aim of the study was to compare scenarios of numerical modeling of the operation of a heart valve bioprosthesis, identifying their advantages and limitations. Material and methods. Numerical modeling was conducted in the Abaqus/ CAE (Dassault Systèmes, France) engineering analysis environment, simulating two cycles of the valve apparatus’s operation. In total, three different computer models were studied, each providing different levels of detail and complexity of the “UniLine” bioprosthesis. Model No.1 was the most simplified and considered only the geometry of the flap; Model No. 2 incorporated elastic connectors with variable stiffness; Model No. 3 included a composite support frame. Qualitative validation of the modeling results was conducted by comparing with the bench tests data obtained on the hydrodynamic stand (ViVitro Labs, Canada) during tests of the corresponding clinical model of the “UniLine” bioprosthesis. Results. One of the setups, Model No. 2, displayed an artificial stress concentration according to Von Mises in the connector attachment area, reaching 2.695 MPa, which is close to the material’s strength limit. Other setups showed a more moderate stress distribution – up to 0.803 and 0.529 MPa. Moreover, it was demonstrated that only Model No. 2 and Model No. 3 reproduce the key effect of the bioprosthesis operation, the mobility of the commissural posts, ensuring a qualitative match with the work in bench conditions. Conclusions. A methodology is proposed that may be useful for conducting further in silico studies of heart valve bioprostheses. Boundary conditions, methods for linking prosthetic components, and opportunities for large-scale “exploratory” studies based on using simplified models are described. The study results confirm the necessity of including all prosthesis components in the numerical model for a more comprehensive and realistic representation of its biomechanics. Such detail contributes to a more accurate safety and effectiveness assessment of the device and can also serve as a foundation for its further optimization.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.241
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueСибирский научный медицинский журналSame topicHydraulic and Pneumatic SystemsFrench-language works237,207