MétaCan
Menu
Back to cohort
Record W4404018007 · doi:10.1101/2024.10.30.621138

A simple, cost-effective microfluidic device using a 3D cross-flow T-junction for producing decellularized extracellular matrix-derived microcarriers

2024· preprint· en· W4404018007 on OpenAlexaff
Farah Kamar, C. Gillis, G. Bischoff, John R. de Bruyn, Lauren E. Flynn, Tamie L. Poepping

Bibliographic record

VenuebioRxiv (Cold Spring Harbor Laboratory) · 2024
Typepreprint
Languageen
FieldMedicine
TopicTissue Engineering and Regenerative Medicine
Canadian institutionsWestern University
Fundersnot available
KeywordsDecellularizationMicrofluidicsMicrocarrierSimple (philosophy)Extracellular matrixMatrix (chemical analysis)Flow (mathematics)Biomedical engineeringMaterials scienceNanotechnologyComputer scienceChemistryCell biologyEngineeringPhysicsCellBiologyMechanicsComposite material

Abstract

fetched live from OpenAlex

ABSTRACT Cell therapies using human mesenchymal stromal cells (MSCs) are promising for a wide variety of clinical applications. However, broad-scale clinical translation is limited by conventional culture methods for MSC expansion within 2D tissue-culture flasks. MSC expansion on ECM-derived microcarriers within stirred bioreactor systems offers a promising approach to support MSC growth. Previously, our team established methods for fabricating ECM-derived microcarriers from a variety of decellularized tissue sources using electrospraying techniques. However, these microcarriers are relatively large and have a broad size distribution, which may limit their utility. Smaller and more uniform microcarriers may be favorable for MSC growth within bioreactors and have greater potential to serve as a minimally invasive injectable cell delivery platform. To address these limitations, the current project focused on the development of a new microfluidic-based approach enabling both uniform and small microcarrier production. Using a novel, modified 3D T-junction design, we successfully generated microcarriers using human decellularized adipose tissue (DAT) as the ECM source. Our new cost-effective device produced microbeads that were small and monodisperse, at a range of flow rate combinations and with high production rates. Photo-crosslinking using rose bengal allowed for the generation of microcarriers that were stable following rehydration, with a mean diameter of 196 ± 47 µm. Following methods optimization and microcarrier characterization, in vitro studies confirmed that the new microcarriers supported human adipose-derived stromal cell (hASC) attachment and growth, as well as ECM production, across 14 days within spinner flask bioreactors. Overall, this study demonstrates the feasibility of using our novel, cost-effective, and reusable microfluidics device to generate cell-supportive microcarriers comprised exclusively of ECM in a size range that could be injected via a small gauge needle and were stable in long-term culture.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.000
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.284
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venuebioRxiv (Cold Spring Harbor Laboratory)Same topicTissue Engineering and Regenerative MedicineFrench-language works237,207