MétaCan
Menu
Back to cohort

Thermal comfort-constrained nonlinear operational optimization of a solar-absorption-radiant cooling system

2024· article· en· W4404024804 on OpenAlexaff
Ahmed E. Elbakhshwan, Muhammed A. Hassan, Mahmoud A. Kassem, Mohamad T. Araji

Bibliographic record

VenueEnergy Conversion and Management · 2024
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsThermal comfortRadiant coolingThermalEnvironmental scienceNuclear engineeringRadiant heatingSolar air conditioningAbsorption (acoustics)ThermodynamicsNonlinear systemMaterials scienceSolar energyMechanicsAerospace engineeringEngineeringPhysicsOpticsElectrical engineering

Abstract

fetched live from OpenAlex

• A thermal comfort-constrained NLP-based optimal controller is developed. • The solar-absorption-radiant cooling system has a solar fraction of 0.8. • Stricter comfort constraints increase the cost and emissions by 30.96% and 37.5%. • Doubling the ventilation rate increases daily operating costs by 19%. • The solar-assisted system saves 45.9% on costs and reduces emissions by 52.5%. With the increasing demand for sustainable building solutions, especially under extreme weather conditions, there is a growing need for renewable-powered cooling systems that can minimize energy consumption and carbon emissions. Solar-absorption-radiant cooling systems offer a promising alternative to traditional air conditioning systems, but their effectiveness relies on efficient control strategies. This study investigates the optimal control of a solar-absorption-radiant cooling system for a single-story office building using non-linear programming (NLP) to minimize operating costs while maintaining thermal comfort. This is achieved by directly integrating the building model and thermal comfort calculations within the optimization procedure. By incorporating a solar collector, storage tank, assisting boiler, and absorption chiller, the system achieves a solar fraction of 0.8, minimizing daily operating costs to 2.11 USD and carbon emissions to ∼ 39.1 k g C O 2 . The system maintains an average PMV of 0.14, an operative temperature of 25.63 °C, and a coefficient of performance of 0.72. The study also explores the impact of varying thermal comfort constraints, ventilation rates, and inlet air temperatures on system performance. Stricter comfort constraints (PMV=-0.2 to 0.2) increase costs and emissions by 30.96 % and 37.5 % respectively, due to increased reliance on the natural gas boiler. Doubling the ventilation rate based on fresh outdoor air increases daily costs and emissions by 19 % and 22.6 % respectively. Conversely, utilizing a supplementary system to supply ventilation air at 25 °C significantly reduces costs and emissions by 26.2 % and 25.4 % respectively, and increases the solar fraction to 0.92. Compared to a conventional system powered solely by a natural gas boiler, the solar-powered system achieves substantial cost savings (45.9 %), reduced carbon emissions (52.5 %), and improved thermal comfort, highlighting the potential of this technology for sustainable building operations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.972
Threshold uncertainty score0.417

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.177
Teacher spread0.172 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueEnergy Conversion and ManagementSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207