Abstract

fetched live from OpenAlex

Single-energy quantitative computed tomography (SEQCT) provides volumetric bone mineral density (vBMD) measures for bone analysis and input to image-based finite element models (FEMs). Dual-energy CT (DECT) improves vBMD by accounting for voxel-specific material variations utilizing scans at multiple x-ray energies. vBMD is also altered by reconstruction kernel that cannot be accounted for using calibration phantoms. This study compared vBMD and FEM stiffness derived from SEQCT and DECT images reconstructed with two common kernels. SEQCT and DECT images of cadaveric shoulders (n = 10) were collected using standard (STD) and boneplus (BONE) kernels. Hounsfield Units were converted to vBMD using specimen-specific calibrations. DECT STD and BONE images were generated using an established material decomposition method with 40 and 90 keV simulated monochromatic images. A proximal humerus bone section below the anatomic neck was used for vBMD analysis and FEM generation. FEMs were loaded to 1% apparent strain for stiffness measurements. Between STD and BONE kernel images, average vBMD differed 0.9 mg K2HPO4 /cc and 4.1 mg K2HPO4 /cc, in SEQCT and DECT images, respectively. Significant differences occurred in DECT images (p = 0.001). BONE reconstructed images produced higher vBMD measures across both SEQCT and DECT images. The difference between STD and BONE in both SEQCT- and DECT-based FEMs persisted, with larger estimated stiffness in BONE models. For six of the models DECT-based had higher stiffness than SEQCT-based models using the same kernel, although these models differed between STD and BONE kernels. Differences in stiffness between STD and BONE derived models were similar across image types (DECT: 17.5 kN/mm; SEQCT: 19.0 kN/mm). Stiffness values were significantly different within SECT kernels and between SEQCT BONE and DECT STD models. This study shows important differences in vBMD and FEM stiffness that occur due to CT-based imaging parameters alone. These results indicate that consistent imaging parameters should be used for vBMD analysis and FEM input to avoid systematic measurement errors.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.921
Threshold uncertainty score0.450

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.205
Teacher spread0.198 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueJournal of BiomechanicsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207