MétaCan
Menu
Back to cohort
Record W4404299823 · doi:10.3390/neurolint16060105

Evaluating the Usability of a Remote Ischemic Conditioning Device for Pre-Hospital Stroke Management: Insights from Paramedic Simulations

2024· article· en· W4404299823 on OpenAlexafffund
Bogna Drozdowska, Kaden Lam, Cody Doolan, Efrem Violato, Aravind Ganesh

Bibliographic record

VenueNeurology International · 2024
Typearticle
Languageen
FieldMedicine
TopicCardiac Ischemia and Reperfusion
Canadian institutionsNorthern Alberta Institute of TechnologyUniversity of Calgary
FundersCanadian Stroke ConsortiumHeart and Stroke Foundation of CanadaUniversity of CalgaryAlberta InnovatesCampus Alberta NeuroscienceFondation Brain Canada
KeywordsMedicineUsabilityMedical emergencyIschemic strokeStroke (engine)Emergency medicineMedical educationHuman–computer interactionPsychiatryIschemiaEngineering

Abstract

fetched live from OpenAlex

BACKGROUND/OBJECTIVES: In acute stroke, often-prolonged hospital transport times present an opportunity for early interventions to salvage brain tissue. Remote ischemic conditioning (RIC), where brief cycles of ischemia-reperfusion in a limb are induced to protect the brain, is a promising treatment for this setting. We assessed the usability of a novel RIC system in a simulated emergency response scenario. METHODS: Paramedics were asked to use the RIC device in an emergency stroke care and ambulance transport simulation, overseen by a confederate. Feedback on device use was collected through questionnaires, including the System Usability Scale (SUS) and the NASA Task Load Index (NASA-TLX), and a semi-structured interview. Questionnaire responses were summarized using descriptive statistics; interview transcripts were analyzed thematically. RESULTS: Nine paramedics (including the confederate) participated, with a mean of 10.0 ± 10.3 years of professional experience. Questionnaire responses indicated high device usability (mean SUS score: 85.3 ± 12.9 out of 100) and low task-related demands, effort, and frustration (mean NASA-TLX domain scores: ≤3.9 out of 20). Seven paramedics stated they would use the device in daily practice. They expressed concerns related to display screen clarity, interference with standard procedures, cable management, device fragility, and patient discomfort. Suggested improvements included adding indicators of device performance and refining the cuff design. CONCLUSIONS: While the device was considered easy to use, paramedics also identified important areas of improvement. With a small, localized study sample, our findings are primarily applicable to the refinement of the RICovery system for use in future clinical trials in the same healthcare setting. However, feedback on the importance of mitigating potential interference of newly introduced procedures with those already established, robustness of equipment, and effective paramedic-patient communication may also help inform the design of other pre-hospital interventions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.021
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.033

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.021
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.002
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.362
Teacher spread0.339 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueNeurology InternationalSame topicCardiac Ischemia and ReperfusionFrench-language works237,207