Verification of the Reliability of an Automated Urine Test Strip Colorimetric Program Using Colorimetric Analysis: Survey Study

2024· article· en· W4404334471 on OpenAlexvenueno aff
Keigo Inagaki, Daisuke Tsuriya, Takuya Hashimoto, Katsumasa Nakamura

Bibliographic record

VenueJMIR Formative Research · 2024
Typearticle
Languageen
FieldEngineering
TopicBiosensors and Analytical Detection
Canadian institutionsnot available
FundersJapan Society for the Promotion of Science
KeywordsPreprintReliability (semiconductor)Test (biology)ColorimetryComputer scienceUrineReliability engineeringChromatographyChemistryEngineeringWorld Wide WebPhysics

Abstract

fetched live from OpenAlex

Background: One method for noninvasive and simple urinary microalbumin testing is urine test strips. However, when visually assessing urine test strips, accurate assessment may be difficult due to environmental influences-such as lighting color and intensity-and the physical and psychological influences of the assessor. These complicate the formation of an objective assessment. objectives: This study developed an "automated urine test strip colorimetric program" (hereinafter referred to as "this program") to objectively assess urine test strips. Using this program may allow urine tests to be conducted at home. In this study, urine samples from hospitalized or outpatient patients were randomly obtained, and the reliability of this program was verified by comparing the agreement rate between this program and an automatic urine analyzer (US-3500 [Eiken Chemical Co, Ltd] and LABOSPECT 006 [Hitachi High-Tech Co, Ltd]). Furthermore, the sensitivity and specificity of the urine albumin test were investigated, and its applicability to screening for microalbuminuria was verified. Methods: A urine test strip was placed in a photography box with constant light intensity and color temperature conditions. The image taken with a smartphone camera on top of the photography box was judged by this program. This program used Accelerated KAZE to perform image-matching processing to reduce the effect of misalignment during photography. It also calculated and judged the item with the smallest color difference between the color chart and the urine test strip using the CIEDE2000 color difference formula. The agreement rate of the results of this program was investigated using the results of an automatic urine analyzer as the gold standard. Results: Compared with the judgments of an automatic urine analyzer, the average agreement rate for 12 items (protein, glucose, urobilinogen, bilirubin, ketone bodies, specific gravity, occult blood, pH, white blood cells, nitrite, creatinine, and albumin) was 78.6%. Furthermore, the average agreement rate of the 12 items within ±1 rank was 95.4%. The results showed a sensitivity of 100% and a specificity of 58.6% in determining albumin in urine, which is important for determining the stage of diabetic nephropathy. Finally, the area under the curve (0.907) derived from the receiver operating characteristic curve was satisfactory. Conclusions: The program developed by the authors can determine urine test strips without requiring calibration in a certain shooting environment. If this program can be used at home to perform urinary microalbumin tests, the early detection and treatment of diabetic nephropathy may prevent the condition from becoming severe.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesBibliometrics
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.330
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.022
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.419
Teacher spread0.353 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJMIR Formative ResearchSame topicBiosensors and Analytical DetectionFrench-language works237,207