MétaCan
Menu
Back to cohort
Record W4404416026 · doi:10.1002/jor.26017

Inducible displacement of cementless total knee arthroplasty components with conventional and weight‐bearing CT‐based radiostereometric analysis

2024· article· en· W4404416026 on OpenAlexafffund
Rebecca A. Hext, Bart L. Kaptein, James L. Howard, Brent A. Lanting, Matthew G. Teeter

Bibliographic record

VenueJournal of Orthopaedic Research® · 2024
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsWestern University
FundersArthritis Society
KeywordsSupine positionMedicineNuclear medicineDisplacement (psychology)ImplantTotal knee arthroplastyOrthodonticsComputed tomographyBiomedical engineeringRadiologySurgery

Abstract

fetched live from OpenAlex

Aseptic loosening remains one of the top causes of revision surgery of total knee arthroplasty (TKA). Radiostereometric analysis (RSA) is used in research to measure implant migration, however limitations prevent its clinical use. New methods have allowed the same measurements as RSA to be performed with computed tomography (CT) scanners (CT-RSA). The objective of this study is to determine inducible displacement measurements from weight-bearing computed tomography (WBCT) and conventional RSA to assess implant stability. Participants (n = 17) completed RSA exams in the supine and standing position, and WBCT exams in the seated (leg extended) and standing position. Double examinations were performed in the seated (WBCT) or supine (RSA) positions. Inducible displacements were measured with model-based RSA (MBRSA) for RSA exams, and a novel CT-RSA software, V3MA, for WBCT exams. Precision of each technique was calculated between double examinations. Precision data for tibial component total translations and rotations were 0.05 mm and 0.118°, respectively with WBCT-RSA, and were 0.108 mm and 0.269°, respectively with MBRSA. MTPM precision was 0.141 mm with WBCT-RSA and was 0.168 mm with MBRSA. Inducible displacement MTPM of the tibial component was 0.244 ± 0.220 mm with WBCT-RSA and 0.662 ± 0.257 mm with MBRSA. Inducible displacement measurements with MBRSA were significantly different from WBCT-RSA for tibial component anterior tilt (p = 0.0002). WBCT-RSA demonstrated comparable precision to MBRSA, and both techniques measured inducible displacements consistent with stable components. Clinical Significance: As the availability of WBCT increases, its use as an alternative to MBRSA is supported to measure the instantaneous fixation of implant components.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.337
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Orthopaedic Research®Same topicTotal Knee Arthroplasty OutcomesFrench-language works237,207