MétaCan
Menu
Back to cohort
Record W4404438138 · doi:10.1016/j.heliyon.2024.e40496

Post-correctional improvement of T2-weighted fast spin echo magnetic resonance imaging pulse sequence for detecting high intensity focused ultrasound thermal lesions

2024· article· en· W4404438138 on OpenAlexafffund
G. S. Lee, Graham A. Ferrier, Jahangir Tavakkoli

Bibliographic record

VenueHeliyon · 2024
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsSt. Michael's HospitalUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of CanadaMitacs
KeywordsPulse sequenceMagnetic resonance imagingUltrasoundEcho (communications protocol)Nuclear magnetic resonancePulse (music)Spin echoFast spin echoIntensity (physics)Materials scienceMedicinePhysicsRadiologyOpticsComputer science

Abstract

fetched live from OpenAlex

High intensity focused ultrasound (HIFU) is a non-invasive therapy that induces heat in a small, localized volume of cancerous tissue without damaging neighbouring vital structures and cells. Precise targeting and treatment monitoring is typically achieved by pairing HIFU with an imaging modality such as magnetic resonance imaging (MRI). The most commonly used MRI pulse sequence for detecting HIFU thermal lesions is the T2-weighted fast spin echo (T2W-FSE) pulse sequence as it provides good contrast between normal and coagulated tissue. The drawbacks of the T2W-FSE pulse sequence are the manifestation of ringing artifacts and the loss of spatial resolution due to the signal modulation in k-space caused by the T2 decay. The inverse Fourier transform (IFT) multiplication scheme aims to remove the signal modulation by incorporating an inverse filter, which is an inverse of the signal modulation trend present in the k-space, to reduce the effects of T2 decay and improve image quality. In this study, four inverse filters (named as regular, narrow, wide, and compound) were developed and implemented on T2W-FSE MR images of ex vivo porcine muscle tissue with HIFU induced thermal lesion using a 0.55 T benchtop MRI research system (Pure Devices, Rimpar, Germany). Offline processing and enhancement of MR images of ex vivo porcine muscle tissue with HIFU induced thermal lesion using the narrow filter yielded the largest improvements of 13.8 ± 2.5 %, 17.0 ± 2.3 %, and 14.4 ± 1.1 % in lateral and axial spatial resolutions, and lesion signal-to-noise ratio (SNR), respectively, compared to the original images. Our results indicate an amplification of the signals in k-space and a reduction in the exponential signal modulation caused by T2 decay. These results also indicate the potential of the IFT multiplication scheme as an image processing method to improve thermal lesion detectability in MR-guided HIFU procedures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.288
Threshold uncertainty score0.552

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.297
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueHeliyonSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207