MétaCan
Menu
Back to cohort
Record W4404562671 · doi:10.1093/ejcts/ezae414

Seven-year outcomes after surgical aortic valve replacement with a stented bovine pericardial bioprosthesis in over 1100 patients: a prospective multicentre analysis

2024· article· en· W4404562671 on OpenAlexaff
Joseph F. Sabik, Vivek Rao, François Dagenais, Michael G. Moront, Michael J. Reardon, Himanshu J. Patel, Jae K. Oh, Shinichi Fukuhara, Louis Labrousse, Ralf Günzinger, Kamran Baig, Saki Ito, Tianhua Wu, Robert J.M. Klautz

Bibliographic record

VenueEuropean Journal of Cardio-Thoracic Surgery · 2024
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsSt. Thomas HospitalToronto General Hospital
FundersMedtronic
KeywordsMedicineAortic valve replacementSurgeryCardiologyHemodynamicsAortic valvePercutaneousInternal medicineProspective cohort studyStenosis

Abstract

fetched live from OpenAlex

OBJECTIVES: Safety, efficacy and durability are important considerations when selecting a bioprosthesis for aortic valve replacement (AVR). This study assessed 7-year clinical outcomes and haemodynamic performance of the Avalus bioprosthesis. METHODS: Patients indicated for surgical AVR were enrolled in this prospective, nonrandomized trial, conducted across 39 sites globally. The primary end-point of this analysis was freedom from surgical explant or percutaneous valve-in-valve reintervention due to structural valve deterioration (SVD) at 7 years of follow-up, determined using Kaplan-Meier (KM) analysis. We also evaluated a composite end-point of SVD and/or severe haemodynamic dysfunction requiring reintervention. Survival, valve-related safety events and haemodynamic performance were assessed. Deaths and safety events were adjudicated by an independent clinical events committee. RESULTS: A total of 1132 patients underwent surgical AVR. Mean age was 70 years; 854 patients (75%) were men. The mean STS risk of mortality was 2.0 ± 1.4%, and 659 patients (58%) had a New York Heart Association classification of I/II. One or more concomitant procedures were performed in 577 patients (51%). At 7 years, the Kaplan-Meier rate of freedom from SVD/severe haemodynamic dysfunction requiring reintervention was 1.2% (0.5-2.5%) with no cases adjudicated as SVD. The survival rate was 82.6% (79.5-85.0%). The KM event rate was 5.7% (4.3-7.7%) for reintervention, 6.3% (4.9-8.3%) for endocarditis and 0.4% (0.1-1.1%) for valve thrombosis. Mean aortic gradient, dimensionless velocity index and effective orifice area were 13.8 ± 5.9 mmHg, 0.42 ± 0.09 and 1.99 ± 0.53 cm2, respectively. CONCLUSIONS: This analysis demonstrated excellent durability of the Avalus valve with good clinical outcomes and stable haemodynamic performance through 7 years of follow-up.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.030
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.006
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.293
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Journal of Cardio-Thoracic SurgerySame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207