MétaCan
Menu
← Back to cohort
Record W4404623735 · doi:10.1088/1361-6560/ad965b

Novel frequency selective B<sub>1</sub> focusing passive lenz resonators for substantial MRI signal-to-noise ratio amplification

2024· article· en· W4404623735 on OpenAlexafffund
Aaron Hodgson, Yurii Shepelytskyi, Viktoriia Batarchuk, Nedal Al Taradeh, Vira Grynko, Mitchell S. Albert

Bibliographic record

VenuePhysics in Medicine and Biology · 2024
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsNOSM UniversityLakehead UniversityThunder Bay Regional Research Institute
FundersNatural Sciences and Engineering Research Council of CanadaMitacs
KeywordsResonatorSignal-to-noise ratio (imaging)AcousticsNoise (video)SIGNAL (programming language)PhysicsMaterials scienceComputer scienceOpticsArtificial intelligence

Abstract

fetched live from OpenAlex

Abstract Objective. The need for increased sensitivity in magnetic resonance imaging (MRI) is crucial for its advancement as an imaging modality. The development of passive Lenz Resonators (LRs) for effective RF magnetic field (B1) focusing will improve MRI sensitivity via local amplification of MRI signal, thereby leading to more efficient diagnosis and patient treatment. Approach. While there are methods for amplifying the signal from specific nuclei in MRI, such as hyperpolarization, a general solution will be more advantageous and would work in combination with these preexisting methods. While the Lenz Lens proposed such a general solution based on Lenz’s law and the reciprocity principle, it came at the cost of limited signal enhancement. In this work, the first-in-kind prototype LR was conceived and examined as a general frequency-selective passive flux-focusing element for significant MRI signal enhancement. A 3.0 T Philips Achieva MRI was used to compare the signal from a phantom in the presence of Lenz Lenses, LRs, and control trials with neither component. Main results. An MRI investigation demonstrated an experimental amplification of the signal-to-noise ratio up to 80% using an MRI insert of two coaxial LRs due to superior B1 focusing. The resonators displayed consistent amplification, nearly independent of their x-position within the MRI bore. Significance. This behavior demonstrates the feasibility of imaging large objects of varying shapes without penalties for signal amplification using LRs. The LRs versatility in geometrical design and consistent signal amplifying abilities between pulse sequences should allow for the development of LRs suitable for most commonly used MRI setups.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.128
GPT teacher head0.406
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and Biology→Same topicAdvanced MRI Techniques and Applications→French-language works237,207→