High detectivity terahertz radiation sensing using frequency-noise-optimized nanomechanical resonators
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
We achieve high detectivity terahertz radiation sensing using a silicon nitride nanomechanical resonator functionalized with a metasurface absorber. High performances are achieved by striking a balance between the frequency stability of the resonator and its responsivity to absorbed radiation. Using this approach, we demonstrate a detectivity D*≈3.4×109cm⋅Hz/W and a noise equivalent power NEP≈36pW/Hz that outperform the best room-temperature on-chip THz detectors, such as pyroelectric detectors, while maintaining a comparable thermal response time of ≈200 ms. Our optical absorber consists of a 1-mm diameter metasurface, which currently enables a 0.5–3 THz detection range but can easily be scaled to other frequencies in the THz and infrared ranges. In addition to demonstrating high-performance terahertz radiation sensing, our work unveils an important fundamental trade-off between frequency stability and responsivity in thermal-based nanomechanical radiation sensors.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it