Development of Panelized Exterior Retrofit Solutions for Commercial and Institutional Buildings
Bibliographic record
Abstract
The total energy used by commercial and institutional buildings in Canada is equivalent to over 10.7 million households.Exterior energy retrofits are over-cladding assemblies that are applied to the building envelope.These retrofits can drastically improve energy efficiency without the time consumption and disruptions of a conventional interior retrofit.This thesis evaluated two potential building envelope solutions for commercial and institutional buildings.One solution used primarily biogenic materials, and the other is based around an all-in-one building enclosure system.Test assemblies of both retrofits were built full-scale for long-term experimental testing.Both solutions provided significant improvements of thermal resistance compared to the original building assembly with little risk for failure at all measured locations.Similarly, modelled and experimental data showed overwhelming evidence that neither solution has potential for moisture damage and mould growth.The results indicate that either solution is viable for commercial and institutional building retrofits.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.005 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".